Literature DB >> 12536141

Stereothresholds with simulated vergence variability and constant error.

Michael T Ukwade1, Harold E Bedell, Ronald S Harwerth.   

Abstract

Stereothresholds are elevated by vergence constant error (fixation disparity), vergence noise, or both. This study investigated the separate and combined effects of simulated vergence constant error and variability on stereothresholds in four normal observers. Targets were 30 arc min bright vertical lines presented separately to the two eyes for 150 ms in darkness. Vergence constant error, simulated as a pedestal disparity, was induced by altering the screen positions of the stereo half-images relative to a previously visible binocular fixation point. Vergence variability was simulated simultaneously by disconjugate motion (amplitude=0-0.5 deg per eye; frequency=2 or 4 Hz) of a pair of scanning mirrors in a Wheatstone stereoscope that was used to present the images to each eye. Various combinations of pedestal disparity and simulated vergence variability produce equivalent stereothresholds whenever the calculated mean deviation (sigma/instantaneous vergence errors//N) of the stimulus from the fixation plane is the same. In particular, stereothresholds are optimal for mean deviations up to approximately 1.4 arc min and then increase according to a power function with an exponent of 0.61. The results imply that vergence constant errors and vergence variability impair stereothresholds because of the resulting mean deviation from the horopter.

Mesh:

Year:  2003        PMID: 12536141     DOI: 10.1016/s0042-6989(02)00409-1

Source DB:  PubMed          Journal:  Vision Res        ISSN: 0042-6989            Impact factor:   1.886


  3 in total

1.  Perceived suprathreshold depth under conditions that elevate the stereothreshold.

Authors:  Harold E Bedell; Liat Gantz; Danielle N Jackson
Journal:  Optom Vis Sci       Date:  2012-12       Impact factor: 1.973

2.  Stereothresholds during Voluntary Head Movement and Disconjugate Image Motion.

Authors:  Harold E Bedell; Dorcas K Tsang; Michael T Ukwade
Journal:  Optom Vis Sci       Date:  2022-01-01       Impact factor: 2.106

3.  LogMAR and Stereoacuity in Keratoconus Corrected with Spectacles and Rigid Gas-permeable Contact Lenses.

Authors:  Vinay Kumar Nilagiri; Sangeetha Metlapally; Parthasarathi Kalaiselvan; Clifton M Schor; Shrikant R Bharadwaj
Journal:  Optom Vis Sci       Date:  2018-04       Impact factor: 1.973

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.