Literature DB >> 12535805

Sirolimus-eluting stent for treatment of complex in-stent restenosis: the first clinical experience.

Muzaffer Degertekin1, Evelyn Regar, Kengo Tanabe, Pieter C Smits, Willem J van der Giessen, Stephan G Carlier, Pim de Feyter, Jeroen Vos, David P Foley, Jurgen M R Ligthart, Jeffrey J Popma, Patrick W Serruys.   

Abstract

OBJECTIVES: In this study, we assess the value of sirolimus eluting stent (SES) implantation in patients with complex in-stent restenosis (ISR).
BACKGROUND: The treatment of ISR remains a therapeutic challenge, since many pharmacological and mechanical approaches have shown disappointing results. The SESs have been reported to be effective in de-novo coronary lesions.
METHODS: Sixteen patients with severe, recurrent ISR in a native coronary artery (average lesion length 18.4 mm) and objective evidence of ischemia were included. They received one or more 18 mm Bx VELOCITY SESs (Cordis Waterloo, Belgium). Quantitative angiographic and three-dimensional intravascular ultrasound (IVUS) follow-up was performed at four months, and clinical follow-up at nine months.
RESULTS: The SES implantation (n = 26) was successful in all 16 patients. Four patients had recurrent restenosis following brachytherapy, and three patients had totally occluded vessels preprocedure. At four months follow-up, one patient had died and three patients had angiographic evidence of restenosis (one in-stent and two in-lesion). In-stent late lumen loss averaged 0.21 mm and the volume obstruction of the stent by IVUS was 1.1%. At nine months clinical follow-up, three patients had experienced four major adverse cardiac events (two deaths and one acute myocardial infarction necessitating repeat target vessel angioplasty).
CONCLUSIONS: The SES implantation in patients with severe ISR lesions effectively prevents neointima formation and recurrent restenosis at four months angiographic follow-up.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12535805     DOI: 10.1016/s0735-1097(02)02704-3

Source DB:  PubMed          Journal:  J Am Coll Cardiol        ISSN: 0735-1097            Impact factor:   24.094


  27 in total

Review 1.  Drug-eluting stents for cardiovascular disorders.

Authors:  Juan F Granada; Grzegorz L Kaluza; Albert Raizner
Journal:  Curr Atheroscler Rep       Date:  2003-07       Impact factor: 5.113

2.  Evidence for "lumen sealing" with sirolimus eluting stents in the treatment of complex coronary artery dissection.

Authors:  E M Wong; C Pawsey; H C Lowe
Journal:  Heart       Date:  2004-03       Impact factor: 5.994

3.  Vascular brachytherapy versus sirolimus eluting stents for the treatment of in-stent restenosis: a prospective registry.

Authors:  J J Goy; P Urban; C Seydoux; P Couke; E De Benedetti; J C Stauffer
Journal:  Heart       Date:  2004-12       Impact factor: 5.994

4.  Intracoronary brachytherapy for the treatment of complex in-stent restenosis.

Authors:  J M Cotton; K Rance; A Patil; M R Thomas
Journal:  Heart       Date:  2005-02       Impact factor: 5.994

Review 5.  Current understanding of coronary in-stent restenosis. Pathophysiology, clinical presentation, diagnostic work-up, and management.

Authors:  T M Schiele
Journal:  Z Kardiol       Date:  2005-11

6.  Superiority of sirolimus eluting stent compared with intracoronary beta radiation for treatment of in-stent restenosis: a matched comparison.

Authors:  E Iofina; P W Radke; P Skurzewski; P K Haager; R Blindt; K-C Koch; P Hanrath; J vom Dahl; R Hoffmann
Journal:  Heart       Date:  2005-03-29       Impact factor: 5.994

7.  The Sirolimus-eluting coronary stent in daily routine practice in Germany: trends in indications over the years. Results from the prospective multi-centre German Cypher Stent Registry.

Authors:  Ralf Zahn; C W Hamm; S Schneider; U Zeymer; G Richardt; M Kelm; B Levenson; T Bonzel; U Tebbe; G Sabin; C A Nienaber; Thomas Pfannebecker; J Senges
Journal:  Clin Res Cardiol       Date:  2007-06-04       Impact factor: 5.460

8.  Treatment of in-stent restenosis with sirolimus-eluting-stents: results from the prospective German Cypher stent registry.

Authors:  Helge Möllmann; Albrecht Elsässer; Holger Nef; Steffen Schneider; Christoph A Nienaber; Gert Richardt; Michael Weber; Malte Kelm; Benny Levenson; Tassilo Bonzel; Ulrich Tebbe; Georg Sabin; Thomas Pfannebecker; Jochen Senges; Christian W Hamm
Journal:  Clin Res Cardiol       Date:  2008-03-03       Impact factor: 5.460

9.  Reduction of intimal hyperplasia in injured rat arteries promoted by catheter balloons coated with polyelectrolyte multilayers that contain plasmid DNA encoding PKCδ.

Authors:  Shane L Bechler; Yi Si; Yan Yu; Jun Ren; Bo Liu; David M Lynn
Journal:  Biomaterials       Date:  2012-10-13       Impact factor: 12.479

10.  Vascular management in rotationplasty.

Authors:  Craig R Mahoney; Curtis W Hartman; Pamela J Simon; B Timothy Baxter; James R Neff
Journal:  Clin Orthop Relat Res       Date:  2008-03-18       Impact factor: 4.176

View more