Literature DB >> 12535767

Automated registration of laser Doppler perfusion images by an adaptive correlation approach: application to focal cerebral ischemia in the rat.

Panomkhawn Riyamongkol1, Weizhao Zhao, Yitao Liu, Ludmila Belayev, Raul Busto, Myron D Ginsberg.   

Abstract

Hemodynamic changes are extremely important in analyzing responses from a brain subjected to a stimulus or treatment. The Laser Doppler technique has emerged as an important tool in neuroscience research. This non-invasive method scans a low-power laser beam in a raster pattern over a tissue surface to generate the time course of images in unit of relative flux changes. Laser Doppler imager (LDI) records cerebral perfusion not only in the temporal but also in the spatial domain. The traditional analysis of LD images has been focused on the region-of-interest (ROI) approach, in which the analytical accuracy in an experiment that necessitates a relative repositioning between the LDI and the scanned tissue area will be weakened due to the operator's subjective decision in data collecting. This report describes a robust image registration method designed to obviate this problem, which is based on the adaptive correlation approach. The assumption in mapping corresponding pixels in two images is to correlate the regions in which these pixels are centered. Based on this assumption, correlation coefficients are calculated between two regions by a method in which one region is moved around over the other in all possible combinations. To avoid ambiguity in distinguishing maximum correlation coefficients, an adaptive algorithm is adopted. Correspondences are then used to estimate the transformation by linear regression. We used a pair of phantom LD images to test this algorithm. A reliability test was also performed on each of the 15 sequential LD images derived from an actual experiment by imposing rotation and translation. The result shows that the calculated transformation parameters (rotation: theta =7.7+/-0.5 degrees; translation: Delta x =2.8+/-0.3, Deltaŷ=4.7+/-0.4) are very close to the prior-set parameters (rotation: theta=8 degrees; translation: Delta x=3, Delta y=5). This result indicates that this approach is a valuable adjunct to LD perfusion monitoring. An original sequence of LD images that recorded cerebral perfusion through a cranial window before, during and after middle cerebral artery occlusion (MCAo) is presented, together with the registered image sequence. Cerebral perfusion data acquired in a pixel-based manner from different anatomic locations of the registered LD image sequence are also presented over the whole time-course of the experiment.

Entities:  

Mesh:

Year:  2002        PMID: 12535767     DOI: 10.1016/s0165-0270(02)00294-7

Source DB:  PubMed          Journal:  J Neurosci Methods        ISSN: 0165-0270            Impact factor:   2.390


  3 in total

1.  Diffuse optical monitoring of repeated cerebral ischemia in mice.

Authors:  Yu Shang; Lei Chen; Michal Toborek; Guoqiang Yu
Journal:  Opt Express       Date:  2011-10-10       Impact factor: 3.894

Review 2.  Standards and pitfalls of focal ischemia models in spontaneously hypertensive rats: with a systematic review of recent articles.

Authors:  Hiroshi Yao; Toru Nabika
Journal:  J Transl Med       Date:  2012-07-06       Impact factor: 5.531

3.  Regulation of cerebrospinal fluid production by caffeine consumption.

Authors:  Myoung-Eun Han; Hak-Jin Kim; Young-Suk Lee; Dong-Hyun Kim; Joo-Taek Choi; Chul-Sik Pan; Sik Yoon; Sun-Yong Baek; Bong-Seon Kim; Jae-Bong Kim; Sae-Ock Oh
Journal:  BMC Neurosci       Date:  2009-09-03       Impact factor: 3.288

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.