Literature DB >> 12535413

Laparoscopic techniques versus open techniques for inguinal hernia repair.

K McCormack1, N W Scott, P M Go, S Ross, A M Grant.   

Abstract

BACKGROUND: Inguinal hernia repair is the most frequently performed operation in general surgery. The standard method for inguinal hernia repair had changed little over a hundred years until the introduction of synthetic mesh. This mesh can be placed by either using an open approach or by using a minimal access laparoscopic technique. Although many studies have explored the relative merits and potential risks of laparoscopic surgery for the repair of inguinal hernia, most individual trials have been too small to show clear benefits of one type of surgical repair over another.
OBJECTIVES: The objective of this review was to compare minimal access laparoscopic mesh techniques with open techniques. Comparisons of open mesh techniques versus open non-mesh techniques have been considered in a separate Cochrane review. SEARCH STRATEGY: We searched MEDLINE, EMBASE, and The Cochrane Central Controlled Trials Registry for relevant randomised controlled trials. The reference list of identified trials, journal supplements, relevant book chapters and conference proceedings were searched for further relevant trials. Through the EU Hernia Trialists Collaboration (EUHTC) communication took place with authors of identified randomised controlled trials to ask for information on any other recent and ongoing trials known to them. Specialists involved in research on the repair of inguinal hernia were contacted to ask for information about any further completed and ongoing trials. The world wide web was also searched. SELECTION CRITERIA: All published and unpublished randomised controlled trials and quasi-randomised controlled trials comparing laparoscopic groin hernia repair with open groin hernia repair were eligible for inclusion. Trials were included irrespective of the language in which they were reported. DATA COLLECTION AND ANALYSIS: Individual patient data were obtained, where possible, from the responsible trialist for all eligible studies. All reanalyses were cross-checked by the reviewers and verified by the trialists before inclusion. Where IPD were unavailable additional aggregate data were sought from trialists and published aggregate data checked and verified by the trialists. IPD were available for 25 trials, additional aggregated data for seven and published data only for nine. Where possible, time to event analysis for hernia recurrence and return to usual activities were performed on an intention to treat principle. The main analyses were based on all trials. Sensitivity analyses based on the data source and trial quality were also performed. Pre-defined subgroup analyses based on recurrent hernias, bilateral hernias and femoral hernias were also carried out. MAIN
RESULTS: 41 published reports of eligible trials were included involving 7161 participants. Sample sizes ranged from 38 to 994, with follow-up from 6 weeks to 36 months. Duration of operation was longer in the laparoscopic groups (WMD 14.81 minutes, 95% CI 13.98 to 15.64; p<0001). Operative complications were uncommon for both methods but more frequent in the laparoscopic group for visceral (Overall 8/2315 versus 1/2599) and vascular (Overall 7/2498 versus 5/2758) injuries. Length of hospital stay did not differ between groups (WMD -0.04 days, 95% CI -0.08 to 0.00; p=0.05, but return to usual activity was earlier for laparoscopic groups (HR 0.56, 95%CI 0.51 to 0.61; p<0.0001 - equivalent to 7 days). The data available showed less persisting pain (Overall 290/2101 versus 459/2399; Peto OR 0.54, 95% CI 0.46 to 0.64; p<0.0001), and less persisting numbness (Overall 102/1419 versus 217/1624; Peto OR 0.38, 95% CI 0.4286 to 0.49; p<0.0001) in the laparoscopic groups. In total, 86 recurrences were reported amongst 3138 allocated laparoscopic repair and 109 amongst 3504 allocated to open repair (Peto OR 0.81, 95% CI 0.61 to 1.08; p = 0.16). The use of mesh during laparoscopic hernia repair is associated with a reduction in the risk of hernia recurrence, significantly so for the transabdominal preperitoneal repair (TAPP) versus open non-mesh repair (overall 26/1440 versus preperitoneal repair (TAPP) versus open non-mesh repair (overall 26/1440 versus 47/1119; Peto OR 0.45, 95% CI 0.28 to 0.72; p=0.0009). However, no difference was detected when comparing laparoscopic methods with open mesh methods of hernia repair. REVIEWER'S
CONCLUSIONS: The use of mesh during laparoscopic hernia repair is associated with a relative reduction in the risk of hernia recurrence of around 30-50%. However, there is no apparent difference in recurrence between laparoscopic and open mesh methods of hernia repair. The data suggests less persisting pain and numbness following laparoscopic repair. Return to usual activities is faster. However, operation times are longer and there appears to be a higher risk of serious complication rate in respect of visceral (especially bladder) and vascular injuries.

Entities:  

Mesh:

Year:  2003        PMID: 12535413     DOI: 10.1002/14651858.CD001785

Source DB:  PubMed          Journal:  Cochrane Database Syst Rev        ISSN: 1361-6137


  258 in total

1.  Comparison of peritoneal closure versus non-closure in laparoscopic trans-abdominal preperitoneal inguinal hernia repair with coated mesh.

Authors:  Erica D Kane; Marc Leduc; Kathryn Schlosser; Nicole Parentela; Donna Wilson; John R Romanelli
Journal:  Surg Endosc       Date:  2017-08-04       Impact factor: 4.584

2.  Synchronous femoral hernias diagnosed during endoscopic inguinal hernia repair.

Authors:  Soni Putnis; April Wong; Christophe Berney
Journal:  Surg Endosc       Date:  2011-06-03       Impact factor: 4.584

3.  [Patient expectations before elective surgery of inguinal hernia. What are the sequelae for ambulatory surgery of inguinal hernia with reference to DRG?].

Authors:  J Zieren; M Paul; H Neuss; J M Muller
Journal:  Chirurg       Date:  2004-05       Impact factor: 0.955

4.  Inguinal hernia: measurement of the biomechanics of the lower abdominal wall and the inguinal canal.

Authors:  T Wolloscheck; A Gaumann; A Terzic; A Heintz; T Junginger; M A Konerding
Journal:  Hernia       Date:  2004-04-20       Impact factor: 4.739

5.  Treating inguinal hernias: editorial does not tell the whole story...

Authors:  Emilie Øberg; Jacob Rosenberg
Journal:  BMJ       Date:  2004-02-14

6.  Surgical management of inguinal hernia: retrospective cohort study in southeastern Scotland, 1985-2001.

Authors:  H D E Atkinson; S G Nicol; S Purkayastha; S Paterson-Brown
Journal:  BMJ       Date:  2004-11-16

7.  Laparoscopic approach to acute abdomen from the Consensus Development Conference of the Società Italiana di Chirurgia Endoscopica e nuove tecnologie (SICE), Associazione Chirurghi Ospedalieri Italiani (ACOI), Società Italiana di Chirurgia (SIC), Società Italiana di Chirurgia d'Urgenza e del Trauma (SICUT), Società Italiana di Chirurgia nell'Ospedalità Privata (SICOP), and the European Association for Endoscopic Surgery (EAES).

Authors:  Ferdinando Agresta; Luca Ansaloni; Gian Luca Baiocchi; Carlo Bergamini; Fabio Cesare Campanile; Michele Carlucci; Giafranco Cocorullo; Alessio Corradi; Boris Franzato; Massimo Lupo; Vincenzo Mandalà; Antonino Mirabella; Graziano Pernazza; Micaela Piccoli; Carlo Staudacher; Nereo Vettoretto; Mauro Zago; Emanuele Lettieri; Anna Levati; Domenico Pietrini; Mariano Scaglione; Salvatore De Masi; Giuseppe De Placido; Marsilio Francucci; Monica Rasi; Abe Fingerhut; Selman Uranüs; Silvio Garattini
Journal:  Surg Endosc       Date:  2012-06-27       Impact factor: 4.584

8.  Laparoscopic extraperitoneal repair versus open inguinal hernia repair: 20-year follow-up of a randomized controlled trial.

Authors:  A Barbaro; H Kanhere; J Bessell; G J Maddern
Journal:  Hernia       Date:  2017-09-01       Impact factor: 4.739

9.  Modified laparoscopic intraperitoneal onlay mesh in complicated inguinal hernia surgery.

Authors:  G M Hyllegaard; H Friis-Andersen
Journal:  Hernia       Date:  2014-04-29       Impact factor: 4.739

10.  Biological tissue adhesive for mesh-application in pigs: an experimental study.

Authors:  S Schulze; V B Kristiansen; B Fischer Hansen; J Rosenberg
Journal:  Surg Endosc       Date:  2004-12-02       Impact factor: 4.584