Literature DB >> 12534711

Computational fluid dynamics analysis of an intra-cardiac axial flow pump.

Ayumi Mitoh1, Tetsuya Yano, Kazumitsu Sekine, Yoshinori Mitamura, Eiji Okamoto, Dong-Wook Kim, Ryohei Yozu, Shiaki Kawada.   

Abstract

A low rate of hemolysis is an important factor for the development of a rotary blood pump. It is, however, difficult to identify the areas where hemolysis occurs. Computational fluid dynamics (CFD) analysis enables the engineer to predict hemolysis on a computer. In this study, fluid dynamics throughout intracardiac axial flow pumps with different designs were analyzed three-dimensionally using CFD software. The computed pressure-flow characteristics of the pump were in good agreement with the measurements. The Reynolds shear stress was computed along particle trace lines. Hemolysis was estimated on the basis of shear stress (tau) and its exposure time (Deltat): dHb/Hb = 3.62 x 10(-7)(tau)(i)(2.416) x Delta(t)(i)(0.785). Particle damage increased with time along the particle trace lines. Hemolysis of each of the pumps was measured in vitro. The computed hemolysis values were in good agreement with the experimental results. CFD is a useful tool for developing a rotary blood pump.

Entities:  

Mesh:

Year:  2003        PMID: 12534711     DOI: 10.1046/j.1525-1594.2003.07190.x

Source DB:  PubMed          Journal:  Artif Organs        ISSN: 0160-564X            Impact factor:   3.094


  6 in total

Review 1.  The use of computational fluid dynamics in the development of ventricular assist devices.

Authors:  Katharine H Fraser; M Ertan Taskin; Bartley P Griffith; Zhongjun J Wu
Journal:  Med Eng Phys       Date:  2010-11-13       Impact factor: 2.242

Review 2.  Mechanical circulatory support devices (MCSD) in Japan: current status and future directions.

Authors:  Setsuo Takatani; Hikaru Matsuda; Akihisa Hanatani; Chisato Nojiri; Kenji Yamazaki; Tadashi Motomura; Katsuhiro Ohuchi; Tohru Sakamoto; Takashi Yamane
Journal:  J Artif Organs       Date:  2005       Impact factor: 1.731

3.  Computational fluid dynamics analysis of blade tip clearances on hemodynamic performance and blood damage in a centrifugal ventricular assist device.

Authors:  Jingchun Wu; Bradley E Paden; Harvey S Borovetz; James F Antaki
Journal:  Artif Organs       Date:  2009-10-12       Impact factor: 3.094

4.  Distribution and history of extensional stresses on vWF surrogate molecules in turbulent flow.

Authors:  Oanh L Pham; Samuel E Feher; Quoc T Nguyen; Dimitrios V Papavassiliou
Journal:  Sci Rep       Date:  2022-01-07       Impact factor: 4.996

5.  Hemolytic Performance in Two Generations of the Sputnik Left Ventricular Assist Device: A Combined Numerical and Experimental Study.

Authors:  Alexandra N Romanova; Alexander A Pugovkin; Maxim V Denisov; Ivan A Ephimov; Dmitry V Gusev; Marian Walter; Thomas Groth; Olga L Bockeria; Tatyana G Le; Anna S Satyukova; Sergey V Selishchev; Dmitry V Telyshev
Journal:  J Funct Biomater       Date:  2022-01-12

6.  Computations of the shear stresses distribution experienced by passive particles as they circulate in turbulent flow: A case study for vWF protein molecules.

Authors:  Oanh L Pham; Samuel E Feher; Quoc T Nguyen; Dimitrios V Papavassiliou
Journal:  PLoS One       Date:  2022-08-29       Impact factor: 3.752

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.