Literature DB >> 12532756

The effect of structures on indoor humidity--possibility to improve comfort and perceived air quality.

C J Simonson1, M Salonvaara, T Ojanen.   

Abstract

The research presented in this paper shows that moisture transfer between indoor air and hygroscopic building structures can generally improve indoor humidity conditions. This is important because the literature shows that indoor humidity has a significant effect on occupant comfort, perceived air quality (PAQ), occupant health, building durability, material emissions, and energy consumption. Therefore, it appears possible to improve the quality of life of occupants when appropriately applying hygroscopic wood-based materials. The paper concentrates on the numerical investigation of a bedroom in a wooden building located in four European countries (Finland, Belgium, Germany, and Italy). The results show that moisture transfer between indoor air and the hygroscopic structure significantly reduces the peak indoor humidity. Based on correlations from the literature, which quantify the effect of temperature and humidity on comfort and PAQ for sedentary adults, hygroscopic structures can improve indoor comfort and air quality. In all the investigated climates, it is possible to improve the indoor conditions such that, as many as 10 more people of 100 are satisfied with the thermal comfort conditions (warm respiratory comfort) at the end of occupation. Similarly, the percent dissatisfied with PAQ can be 25% lower in the morning when permeable and hygroscopic structures are applied.

Entities:  

Mesh:

Year:  2002        PMID: 12532756     DOI: 10.1034/j.1600-0668.2002.01128.x

Source DB:  PubMed          Journal:  Indoor Air        ISSN: 0905-6947            Impact factor:   5.770


  2 in total

1.  Analysis of indoor air pollutants checklist using environmetric technique for health risk assessment of sick building complaint in nonindustrial workplace.

Authors:  Ai Syazwan; B Mohd Rafee; Hafizan Juahir; Azf Azman; Am Nizar; Z Izwyn; K Syahidatussyakirah; Aa Muhaimin; Ma Syafiq Yunos; Ar Anita; J Muhamad Hanafiah; Ms Shaharuddin; A Mohd Ibthisham; I Mohd Hasmadi; Mn Mohamad Azhar; Hs Azizan; I Zulfadhli; J Othman; M Rozalini; Ft Kamarul
Journal:  Drug Healthc Patient Saf       Date:  2012-09-21

2.  Development of an indoor air quality checklist for risk assessment of indoor air pollutants by semiquantitative score in nonindustrial workplaces.

Authors:  Ai Syazwan; B Mohd Rafee; Juahir Hafizan; Azf Azman; Am Nizar; Z Izwyn; Aa Muhaimin; Ma Syafiq Yunos; Ar Anita; J Muhamad Hanafiah; Ms Shaharuddin; A Mohd Ibthisham; Mohd Hasmadi Ismail; Mn Mohamad Azhar; Hs Azizan; I Zulfadhli; J Othman
Journal:  Risk Manag Healthc Policy       Date:  2012-04-13
  2 in total