Literature DB >> 12530831

Detection of ATP-induced nitric oxide in a biomimetic circulatory vessel containing an immobilized endothelium.

Damian H Kotsis1, Dana M Spence.   

Abstract

Conditions for the adhesion of bovine pulmonary artery endothelial cells (bPAECs) in microbore tubing of 250-microm i.d. are described. When immobilized to the lumen of microbore tubing, these cells represent a mimic of a circulatory vessel's endothelium. The microbore tubing is coated with 100 microg mL(-1) fibronectin in order to promote bPAEC adhesion to the lumen of the tubing. A series of micrographs of the cells inside of the tubing indicates that approximately 3.5 h is necessary for cell adhesion. In this study, adenosine triphosphate (ATP) is used to induce the release of nitric oxide from the endothelium mimic. The endothelium-derived NO is detected amperometrically at a parallel flow cell containing a glassy carbon working electrode modified with Nafion. Results indicate that detectable amounts of NO are only produced by the endothelium mimic when ATP is present in the buffer. The typical concentration of NO produced by the endothelium mimic upon the introduction of 100 microM ATP is approximately 0.80 microM. Based on the injection volume of ATP and the estimated number of cells on the tubing lumen, this value corresponds to approximately 1 amol of NO/cell. Moreover, shear stress alone does not provide the agonistic effect required for NO production in the submicromolar range.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12530831     DOI: 10.1021/ac0258249

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  5 in total

1.  A microfluidic system to study cytoadhesion of Plasmodium falciparum infected erythrocytes to primary brain microvascularendothelial cells.

Authors:  Thurston Herricks; Karl B Seydel; George Turner; Malcolm Molyneux; Robert Heyderman; Terrie Taylor; Pradipsinh K Rathod
Journal:  Lab Chip       Date:  2011-07-11       Impact factor: 6.799

2.  A microchip-based endothelium mimic utilizing open reservoirs for cell immobilization and integrated carbon ink microelectrodes for detection.

Authors:  Matthew K Hulvey; R Scott Martin
Journal:  Anal Bioanal Chem       Date:  2008-11-07       Impact factor: 4.142

3.  Surface modification of a perfluorinated ionomer using a glow discharge deposition method to control protein adsorption.

Authors:  Thelma I Valdes; Winston Ciridon; Buddy D Ratner; James D Bryers
Journal:  Biomaterials       Date:  2007-12-21       Impact factor: 12.479

4.  Detection of nitric oxide production in cell cultures by luciferin-luciferase chemiluminescence.

Authors:  Yakov Y Woldman; Tim D Eubank; Andrew J Mock; Natalia C Stevens; Saradhadevi Varadharaj; Jenifer Turco; Mikhail A Gavrilin; Bruce R Branchini; Valery V Khramtsov
Journal:  Biochem Biophys Res Commun       Date:  2015-08-04       Impact factor: 3.575

5.  Patterned electrode-based amperometric gas sensor for direct nitric oxide detection within microfluidic devices.

Authors:  Wansik Cha; Yi-Chung Tung; Mark E Meyerhoff; Shuichi Takayama
Journal:  Anal Chem       Date:  2010-04-15       Impact factor: 6.986

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.