Literature DB >> 12529461

Pseudomonas aeruginosa and Serratia marcescens contamination associated with a manufacturing defect in bronchoscopes.

David L Kirschke1, Timothy F Jones, Allen S Craig, Patricia S Chu, Glenda G Mayernick, Jayesh A Patel, William Schaffner.   

Abstract

BACKGROUND: Several outbreaks and pseudo-outbreaks of Pseudomonas aeruginosa and Serratia marcescens infections associated with bronchoscopy have been reported. We conducted an investigation of P. aeruginosa and S. marcescens isolates related to bronchoscopy at a community hospital.
METHODS: We reviewed the records of all bronchoscopic procedures at the community hospital from July to October 2001. Environmental samples were obtained. Pulsed-field gel electrophoresis (PFGE) was performed on isolates of P. aeruginosa.
RESULTS: From July 1 to October 31, 2001, 66 bronchoscopic procedures were performed in 60 patients, and 43 specimens were obtained for bacterial culture; 20 of the specimens (47 percent) were positive for P. aeruginosa. Six (30 percent) of the specimens that were positive for P. aeruginosa also yielded S. marcescens. All 20 P. aeruginosa isolates were associated with procedures performed with three of four new bronchoscopes from the same manufacturer. Contrary to manufacturing specifications, the biopsy-port caps on all four bronchoscopes were easily removable, and P. aeruginosa was cultured from the biopsy ports of the three implicated bronchoscopes. The PFGE patterns of P. aeruginosa isolates from the bronchoscopes, patients, and two environmental samples were indistinguishable. One patient was hospitalized with P. aeruginosa pneumonia 11 days after bronchoscopy. The manufacturer reported a design change instituted in 1997, and production problems may have resulted in the distribution of bronchoscopes that did not meet specifications.
CONCLUSIONS: We documented contamination of bronchoscopes with P. aeruginosa and S. marcescens and possible infection of patients at a community hospital as a result of the inadequate disinfection of bronchoscopes because of a manufacturing defect. Copyright 2003 Massachusetts Medical Society

Entities:  

Mesh:

Year:  2003        PMID: 12529461     DOI: 10.1056/NEJMoa021791

Source DB:  PubMed          Journal:  N Engl J Med        ISSN: 0028-4793            Impact factor:   91.245


  23 in total

1.  Epidemiology and Prevention of Infections Related to Endoscopy.

Authors:  Arjun Srinivasan
Journal:  Curr Infect Dis Rep       Date:  2003-12       Impact factor: 3.725

2.  2007 Guideline for Isolation Precautions: Preventing Transmission of Infectious Agents in Health Care Settings.

Authors:  Jane D Siegel; Emily Rhinehart; Marguerite Jackson; Linda Chiarello
Journal:  Am J Infect Control       Date:  2007-12       Impact factor: 2.918

3.  Efflux as a glutaraldehyde resistance mechanism in Pseudomonas fluorescens and Pseudomonas aeruginosa biofilms.

Authors:  Amit Vikram; Jennifer M Bomberger; Kyle J Bibby
Journal:  Antimicrob Agents Chemother       Date:  2015-03-30       Impact factor: 5.191

Review 4.  National athletic trainers' association position statement: skin diseases.

Authors:  Steven M Zinder; Rodney S W Basler; Jack Foley; Chris Scarlata; David B Vasily
Journal:  J Athl Train       Date:  2010 Jul-Aug       Impact factor: 2.860

5.  Molecular genetic investigations of contaminated contact lens storage cases as reservoirs of Pseudomonas aeruginosa keratitis.

Authors:  Yoko Ogushi; Hiroshi Eguchi; Tomomi Kuwahara; Naoko Hayabuchi; Masako Kawabata
Journal:  Jpn J Ophthalmol       Date:  2010-12-30       Impact factor: 2.447

6.  Controlled prospective randomised trial on the effects on pulmonary haemodynamics of the ambulatory long term use of nitric oxide and oxygen in patients with severe COPD.

Authors:  K Vonbank; R Ziesche; T W Higenbottam; L Stiebellehner; V Petkov; P Schenk; P Germann; L H Block
Journal:  Thorax       Date:  2003-04       Impact factor: 9.139

Review 7.  Transmission of infection by flexible gastrointestinal endoscopy and bronchoscopy.

Authors:  Julia Kovaleva; Frans T M Peters; Henny C van der Mei; John E Degener
Journal:  Clin Microbiol Rev       Date:  2013-04       Impact factor: 26.132

Review 8.  Klebsiella spp. in endoscopy-associated infections: we may only be seeing the tip of the iceberg.

Authors:  P Gastmeier; R-P Vonberg
Journal:  Infection       Date:  2013-10-29       Impact factor: 3.553

9.  A bronchofiberoscopy-associated outbreak of multidrug-resistant Acinetobacter baumannii in an intensive care unit in Beijing, China.

Authors:  Yukun Xia; CuiLing Lu; Jingya Zhao; Gaige Han; Yong Chen; Fang Wang; Bin Yi; Guoqin Jiang; Xiaohua Hu; Xianfeng Du; Zheng Wang; Hong Lei; Xuelin Han; Li Han
Journal:  BMC Infect Dis       Date:  2012-12-03       Impact factor: 3.090

10.  Modeling microbial survival in buildup biofilm for complex medical devices.

Authors:  Michelle J Alfa; Rosemarie Howie
Journal:  BMC Infect Dis       Date:  2009-05-08       Impact factor: 3.090

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.