Literature DB >> 12527967

Maximal oxygen uptake during field running does not exceed that measured during treadmill exercise.

T Meyer1, J-P Welter, J Scharhag, W Kindermann.   

Abstract

Modern ergometric equipment enables the simulation of laboratory maximal oxygen uptake (.VO(2max)) testing in the field. Therefore, it was investigated whether the improved event specificity on the track might lead to higher .VO(2max) measurements in running. Identical protocols were used on the treadmill and on the track (speed was indicated by a computer-driven flashing light system). Ambulatory measurements of gas exchange were carried out throughout both tests, which were executed in randomized order. There were no significant differences ( P=0.71) in .VO(2max) between treadmill [4.65 (0.51) ml.min(-1)] and field tests [4.63 (0.55) ml.min(-1)]. However, the test duration differed significantly ( P<0.001) by approximately 5%: treadmill 691 (39) s; field test 727 (42) s. With the exception of maximum heart rate (HR(max); significantly higher in the field with P=0.02) all criteria for the degree of effort were similar between the two tests. However, the difference in HR(max) at less than 2 beats.min(-1), was practically negligible. Submaximal measurements of oxygen uptake and minute ventilation were significantly higher on the treadmill ( P<0.001 for both parameters). In summary, field tests with incremental running protocols do not result in higher .VO(2max) measurements compared to laboratory treadmill exercise. A better running economy on the track results in higher maximal velocities and longer exercise durations being sustained. The determination of .VO(2max) is not a reasonable application for ambulatory gas exchange measurements because laboratory values are not surpassed.

Entities:  

Mesh:

Year:  2002        PMID: 12527967     DOI: 10.1007/s00421-002-0718-x

Source DB:  PubMed          Journal:  Eur J Appl Physiol        ISSN: 1439-6319            Impact factor:   3.078


  12 in total

1.  Physiological responses to nordic walking, walking and jogging.

Authors:  Thorsten Schiffer; Axel Knicker; Uwe Hoffman; Brigitte Harwig; Wildor Hollmann; Heiko K Strüder
Journal:  Eur J Appl Physiol       Date:  2006-06-24       Impact factor: 3.078

2.  Criteria for determination of maximal oxygen uptake: a brief critique and recommendations for future research.

Authors:  Adrian W Midgley; Lars R McNaughton; Remco Polman; David Marchant
Journal:  Sports Med       Date:  2007       Impact factor: 11.136

3.  Discrepancy between training, competition and laboratory measures of maximum heart rate in NCAA division 2 distance runners.

Authors:  Katherine Semin; Alvah C Stahlnecker Iv; Kate Heelan; Gregory A Brown; Brandon S Shaw; Ina Shaw
Journal:  J Sports Sci Med       Date:  2008-12-01       Impact factor: 2.988

4.  A Systematic Review and Meta-Analysis of Crossover Studies Comparing Physiological, Perceptual and Performance Measures Between Treadmill and Overground Running.

Authors:  Jayme R Miller; Bas Van Hooren; Chris Bishop; Jonathan D Buckley; Richard W Willy; Joel T Fuller
Journal:  Sports Med       Date:  2019-05       Impact factor: 11.136

5.  Better economy in field running than on the treadmill: evidence from high-level distance runners.

Authors:  M Mooses; B Tippi; K Mooses; J Durussel; J Mäestu
Journal:  Biol Sport       Date:  2015-03-15       Impact factor: 2.806

6.  The effect of trial familiarisation on the validity and reproducibility of a field-based self-paced VO2max test.

Authors:  W Lim; D Lambrick; A R Mauger; B Woolley; J Faulkner
Journal:  Biol Sport       Date:  2016-07-02       Impact factor: 2.806

7.  The effect of treadmill-based and track-based walking training on physical fitness in ankle-sprain experienced young people.

Authors:  Eunsook Sung
Journal:  J Exerc Rehabil       Date:  2017-02-28

8.  Age-Predicted Maximal Heart Rate in Recreational Marathon Runners: A Cross-Sectional Study on Fox's and Tanaka's Equations.

Authors:  Pantelis T Nikolaidis; Thomas Rosemann; Beat Knechtle
Journal:  Front Physiol       Date:  2018-03-15       Impact factor: 4.566

9.  Non-motorized Treadmill Running Is Associated with Higher Cardiometabolic Demands Compared with Overground and Motorized Treadmill Running.

Authors:  Robert B Edwards; Paul J Tofari; Stuart J Cormack; Douglas G Whyte
Journal:  Front Physiol       Date:  2017-11-14       Impact factor: 4.566

10.  A novel method for calculating the energy cost of turning during running.

Authors:  Yoichi Hatamoto; Yosuke Yamada; Tatsuya Fujii; Yasuki Higaki; Akira Kiyonaga; Hiroaki Tanaka
Journal:  Open Access J Sports Med       Date:  2013-05-09
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.