Literature DB >> 12525584

Implications of problematic access in transluminal endografting of abdominal aortic aneurysm.

Megumi N Mathison1, Gary J Becker, Barry T Katzen, James F Benenati, Gerald Zemel, Alex Powell, Marjorie M Lima.   

Abstract

PURPOSE: Despite careful preoperative assessment, problematic access to the abdominal aorta for transluminal endografting (TE) of abdominal aortic aneurysm (AAA) is sometimes encountered. This study identifies preoperative risk factors predictive of problematic access and determines the impact of problematic access on outcomes.
MATERIALS AND METHODS: Three hundred twenty-one consecutive TE procedures for AAA were divided into two groups: group A, which had access problems (n = 74), and group B, which had none (n = 247).
RESULTS: Logistic regression analysis of risk factors showed that (i) a pulmonary risk score of 3 (P <.001; odds ratio, 11.2), (ii) a hyperlipidemia score of 3 (P =.004; odds ratio, 2.6), and (iii) a small body (short height with low weight, P =.003; odds ratio, of 4.2) were independent risk factors for problematic access. Outcomes compared included rates of perioperative mortality, aborted procedure, surgical conversion, major complication, limb complication, and endoleak. The perioperative mortality rate was higher in group A (6.8% vs 1.2%; P =.018) and procedures were more likely to be aborted in patients in group A (12.2% vs 0%; P <.001). Rates of surgical conversion, major complication, and limb complication were not different between the two groups. The endoleak rate was higher in group B (10.8% vs 26.7%; P =.004). Logistic regression analysis showed that problematic access was an independent risk factor (P =.004; odds ratio, 12.0) for perioperative mortality.
CONCLUSIONS: Moderate to severe chronic obstructive pulmonary disease and hyperlipidemia, both risk factors for atherosclerosis, were related to problematic access in this series. Small body size was another factor related to problematic access. Problematic access was an independent risk factor for perioperative mortality.

Entities:  

Mesh:

Year:  2003        PMID: 12525584

Source DB:  PubMed          Journal:  J Vasc Interv Radiol        ISSN: 1051-0443            Impact factor:   3.464


  1 in total

1.  Ultra-low profile polymer-filled stent graft for abdominal aortic aneurysm treatment: a two-year follow-up.

Authors:  Anna Maria Ierardi; Dimitrios Tsetis; Christos Ioannou; Domenico Laganà; Chiara Floridi; Mario Petrillo; Antonio Pinto; Gabriele Piffaretti; Gianpaolo Carrafiello
Journal:  Radiol Med       Date:  2015-01-29       Impact factor: 3.469