In vitro and in vivo degradation of biomimetic octacalcium phosphate and carbonate apatite coatings on titanium implants.

F Barrère1, C M van der Valk, R A J Dalmeijer, C A van Blitterswijk, K de Groot, P Layrolle.   

Abstract

Calcium phosphate (Ca-P) coatings have been applied onto titanium alloys prosthesis to combine the srength of metals with the bioactivity of Ca-P. It has been clearly shown in many publications that Ca-P coating accelerates bone formation around the implant. However, longevity of the Ca-P coating for an optimal bone apposition onto the prosthesis remains controversial. Biomimetic bone-like carbonate apatite (BCA) and Octacalcium Phosphate (OCP) coatings were deposited on Ti6Al4V samples to evaluate their in vitro and in vivo dissolution properties. The coated plates were soaked in alpha-MEM for 1, 2, and 4 weeks, and they were analyzed by Back Scattering Electron Microscopy (BSEM) and by Fourier Transform Infra Red spectroscopy (FTIR). Identical coated plates were implanted subcutaneously in Wistar rats for similar periods. BSEM, FTIR, and histomorphometry were performed on the explants. In vitro and in vivo, a carbonate apatite (CA) formed onto OCP and BCA coatings via a dissolution-precipitation process. In vitro, both coatings dissolved overtime, whereas in vivo BCA calcified and OCP partially dissolved after 1 week. Thereafter, OCP remained stable. This different in vivo behavior can be attributed to (1) different organic compounds that might prevent or enhance Ca-P dissolution, (2) a greater reactivity of OCP due to its large open structure, or (3) different thermodynamic stability between OCP and BCA phases. These structural and compositional differences promote either the progressive loss or calcification of the Ca-P coating and might lead to different osseointegration of coated implants. Copyright 2002 Wiley Periodicals, Inc. J Biomed Mater Res 64A: 378-387, 2003

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12522826     DOI: 10.1002/jbm.a.10291

Source DB:  PubMed          Journal:  J Biomed Mater Res A        ISSN: 1549-3296            Impact factor:   4.396


  27 in total

1.  Clinical evaluation of anodized surface implants submitted to a counter torque of 25 ncm after 60 days of osseointegration: study in humans.

Authors:  Rafael Manfro; Marcelo Carlos Bortoluzzi; Vinícius Fabris; Carlos Nelson Elias; Vera Cavalcanti de Araújo
Journal:  J Maxillofac Oral Surg       Date:  2013-09-13

2.  The effect of mineral coating morphology on mesenchymal stem cell attachment and expansion.

Authors:  Siyoung Choi; William L Murphy
Journal:  J Mater Chem       Date:  2012-12-28

3.  Regulation of bone-related genes expression by bone-like apatite in MC3T3-E1 cells.

Authors:  Y F Tan; S F Hong; X L Wang; J Lu; H Wang; X D Zhang
Journal:  J Mater Sci Mater Med       Date:  2007-06-28       Impact factor: 3.896

4.  Fabrication of strongly attached hydroxyapatite coating on titanium by hydrothermal treatment of Ti-Zn-PO4 coated titanium in CaCl 2 solution.

Authors:  Alireza Valanezhad; Kanji Tsuru; Kunio Ishikawa
Journal:  J Mater Sci Mater Med       Date:  2015-07-16       Impact factor: 3.896

5.  Gradual pore formation in natural origin scaffolds throughout subcutaneous implantation.

Authors:  Ana M Martins; James D Kretlow; Ana R Costa-Pinto; Patrícia B Malafaya; Emanuel M Fernandes; Nuno M Neves; Catarina M Alves; Antonios G Mikos; F Kurtis Kasper; Rui L Reis
Journal:  J Biomed Mater Res A       Date:  2011-12-30       Impact factor: 4.396

6.  In vivo evaluation of cp Ti implants with modified surfaces by laser beam with and without hydroxyapatite chemical deposition and without and with thermal treatment: topographic characterization and histomorphometric analysis in rabbits.

Authors:  Thallita Pereira Queiroz; Rafael Scaf de Molon; Francisley Ávila Souza; Rogério Margonar; Anahi Herrera Aparecida Thomazini; Antônio Carlos Guastaldi; Eduardo Hochuli-Vieira
Journal:  Clin Oral Investig       Date:  2016-08-16       Impact factor: 3.573

Review 7.  Substituted hydroxyapatite coatings of bone implants.

Authors:  Daniel Arcos; María Vallet-Regí
Journal:  J Mater Chem B       Date:  2020-03-04       Impact factor: 6.331

8.  Peripheral mineralization of a 3D biodegradable tubular construct as a way to enhance guidance stabilization in spinal cord injury regeneration.

Authors:  A L Oliveira; E C Sousa; N A Silva; N Sousa; A J Salgado; R L Reis
Journal:  J Mater Sci Mater Med       Date:  2012-08-19       Impact factor: 3.896

9.  The adsorption of preferential binding peptides to apatite-based materials.

Authors:  Sharon J Segvich; Hayes C Smith; David H Kohn
Journal:  Biomaterials       Date:  2008-12-18       Impact factor: 12.479

10.  Preparation and characterization of porous alginate scaffolds containing various amounts of octacalcium phosphate (OCP) crystals.

Authors:  Naru Shiraishi; Takahisa Anada; Yoshitomo Honda; Taisuke Masuda; Keiichi Sasaki; Osamu Suzuki
Journal:  J Mater Sci Mater Med       Date:  2009-10-23       Impact factor: 3.896

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.