Literature DB >> 12522700

Optimal operative strategies in repair of juxtarenal abdominal aortic aneurysms.

Cynthia K Shortell1, Marcia Johansson, Richard M Green, Karl A Illig.   

Abstract

In an effort to identify preoperative and perioperative factors impacting outcome in repair of juxtarenal abdominal aortic aneurysm (JRAAA), hospital records and CT scans (for calcification, intraluminal thrombus, and aortic diameter) of all patients undergoing JRAAA repair over the past 10 years were reviewed. The 87 men and 25 women had a mean age of 72, and a mean maximal aortic diameter of 6.2 cm. Renal artery stenosis (RAS) and iliac disease were present in 13 (11%) and 40 patients (35%), respectively. Comorbidities included coronary artery disease (n = 49, 44%), COPD (n = 28, 25%), diabetes mellitus (n = 10, 9%), and preoperative renal insufficiency (PRI; Cr >1.4 mg/dL; n = 14, 12%). A midline incision was used in most of the patients (n = 98, 88%). The proximal aortic clamp was placed in the supraceliac (SC) position in 92 (82%) patients, and directly above one or both renal arteries in 20 (18%) patients. The overall mortality was 6% (n = 7). Cardiac complications occurred in 26 patients (23%); pulmonary, in 22 (20%); renal, in 14 (12%); and gastrointestinal, in 10 (9%). No patient experienced mesenteric ischemia. Mean elevation in creatinine was greater in patients with PRI (1.8 mg/dL vs. 0.13 mg/dL, p = 0.04). Mean blood loss (EBL) was 2701 +/- 189 cc, and mean LOS was 16.1 +/- 1.7 days. Age >70 was associated with increased length of stay (LOS) (12.1 days vs. 18.6 days, p = 0.05) and higher mortality (0 vs. 10%, p = 0.02); otherwise there were no significant relationships between pre- and perioperative parameters and any of the measured outcomes including death, postoperative RI, and LOS. Preferential SC clamping may substantially reduce complications of JRAAA repair (such as mesenteric and renal ischemia) related to proximal cuff disease, but cannot overcome the deleterious affects of advanced age and PRI.

Entities:  

Mesh:

Year:  2003        PMID: 12522700     DOI: 10.1007/s10016-001-0336-9

Source DB:  PubMed          Journal:  Ann Vasc Surg        ISSN: 0890-5096            Impact factor:   1.466


  7 in total

1.  Predictive factors for mortality after open repair of paravisceral abdominal aortic aneurysm.

Authors:  Prateek K Gupta; Jason N Mactaggart; Bala Natarajan; Thomas G Lynch; Shipra Arya; Himani Gupta; Xiang Fang; Iraklis I Pipinos
Journal:  J Vasc Surg       Date:  2011-12-30       Impact factor: 4.268

2.  Comparative early and midterm results of open juxtarenal and infrarenal aneurysm repair.

Authors:  Stefan Ockert; Hardy Schumacher; Dittmar Böckler; Katrin Malcherek; Jochen Hansmann; Jens Allenberg
Journal:  Langenbecks Arch Surg       Date:  2007-01-23       Impact factor: 3.445

3.  Patient selection and perioperative outcomes are similar between targeted and nontargeted hospitals (in the National Surgical Quality Improvement Program) for abdominal aortic aneurysm repair.

Authors:  Peter A Soden; Sara L Zettervall; Klaas H J Ultee; Jeremy D Darling; John C McCallum; Allen D Hamdan; Mark C Wyers; Marc L Schermerhorn
Journal:  J Vasc Surg       Date:  2016-07-25       Impact factor: 4.268

4.  Temporary extracorporeal axillo-iliac vascular prosthesis shunt in open repair of a pararenal aortic aneurysm.

Authors:  Einar Dregelid
Journal:  Int J Surg Case Rep       Date:  2013-01-28

5.  Early experience with fenestrated stent grafts for treatment of juxtarenal aortic aneurysm.

Authors:  Naoki Unno; Naoto Yamamoto; Wataru Higashiura; Minoru Suzuki; Yuuki Mano; Masaki Sano; Takaaki Saito; Ryota Sugisawa; Hiroyuki Konno
Journal:  Ann Vasc Dis       Date:  2013-09-05

6.  Renal and abdominal visceral complications after open aortic surgery requiring supra-renal aortic cross clamping.

Authors:  Shin-Seok Yang; Keun-Myoung Park; Young-Nam Roh; Yang Jin Park; Dong-Ik Kim; Young-Wook Kim
Journal:  J Korean Surg Soc       Date:  2012-08-27

7.  Atheroembolization and potential air embolization during aortic declamping in open repair of a pararenal aortic aneurysm: A case report.

Authors:  Einar Børre Dregelid; Peer Kåre Lilleng
Journal:  Int J Surg Case Rep       Date:  2016-04-13
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.