Literature DB >> 12522648

Slowly developing perigraft seroma after a modified Blalock-Taussig shunt.

K Matsuyama1, M Matsumoto, T Sugita, T Matsuo.   

Abstract

We report a 26-year-old patient with slowly developing perigraft seroma 15 years after a modified Blalock-Taussig shunt with an expanded polytetrafluorethylene graft. The mediastinal mass was first observed on a chest x-ray film 8 years after the shunt operation. The mass contained massive gelatinous or organic tissues with a severely calcified pseudocapsule, and it was adjacent to the calcified but functioning graft. No fluid collections were noted. The histological findings were compatible with a seroma. No recurrence was noted on last follow-up 1 year postoperatively.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12522648     DOI: 10.1007/s00246-002-0373-3

Source DB:  PubMed          Journal:  Pediatr Cardiol        ISSN: 0172-0643            Impact factor:   1.655


  9 in total

1.  Failure of knitted dacron as an arterial prosthesis.

Authors:  R M Blumenberg; M L Gelfand
Journal:  Surgery       Date:  1977-05       Impact factor: 3.982

2.  Chronic perigraft seromas in PTFE grafts.

Authors:  E Borrero; W Doscher
Journal:  J Cardiovasc Surg (Torino)       Date:  1988 Jan-Feb       Impact factor: 1.888

3.  The modified polytetrafluoroethylene Blalock-Taussig shunt: case report of an unusual complication.

Authors:  L Noyez; W Daenen
Journal:  J Thorac Cardiovasc Surg       Date:  1987-10       Impact factor: 5.209

4.  A computer simulation of the plasma leakage through a vascular prosthesis made of expanded polytetrafluoroethylene.

Authors:  R Tabata; T Kobayashi; A Mori; S Matsuno; S Watarida; M Onoe; T Sugita; S Shiraisi; T Nojima
Journal:  J Thorac Cardiovasc Surg       Date:  1993-04       Impact factor: 5.209

5.  Development of a perigraft seroma around modified Blalock-Taussig shunts: imaging evaluation.

Authors:  Rick R van Rijn; Rolf M F Berger; Maarten H Lequin; Simon G F Robben
Journal:  AJR Am J Roentgenol       Date:  2002-03       Impact factor: 3.959

6.  Heparin as a risk factor for perigraft seroma complicating the modified Blalock-Taussig shunt.

Authors:  R M Berger; G Bol-Raap; W J Hop; A J Bogers; J Hess
Journal:  J Thorac Cardiovasc Surg       Date:  1998-08       Impact factor: 5.209

7.  Serous fluid leakage: a complication following the modified Blalock-Taussig shunt.

Authors:  J LeBlanc; R Albus; W G Williams; C A Moes; G Wilson; R M Freedom; G A Trusler
Journal:  J Thorac Cardiovasc Surg       Date:  1984-08       Impact factor: 5.209

8.  Perigraft seroma: clinical, histologic, and serologic correlates.

Authors:  S S Ahn; H I Machleder; R Gupta; W S Moore
Journal:  Am J Surg       Date:  1987-08       Impact factor: 2.565

9.  Perigraft seromas complicating arterial grafts.

Authors:  R M Blumenberg; M L Gelfand; W A Dale
Journal:  Surgery       Date:  1985-02       Impact factor: 3.982

  9 in total
  2 in total

1.  Post Blalock-Taussig shunt mediastinal mass - a single shadow with two different destinies.

Authors:  Manoj Kumar Rohit; Ramalingam Vadivelu; Niranjan Khandelwal; Satheesh Krishna
Journal:  Indian Heart J       Date:  2014-02-22

2.  Late onset seroma post-thymectomy presenting as cardiac tamponade.

Authors:  Dilli Ram Poudel; Smith Giri; Ranjan Pathak; Mohamed Morsey; Shadwan Alsafwah
Journal:  J Community Hosp Intern Med Perspect       Date:  2015-06-15