Literature DB >> 12522403

Anterograde arthroscopic fixation of avulsion fractures of the tibial eminence with a cannulated screw: five-year results.

Vladimir Senekovic1, Matjaz Veselko.   

Abstract

PURPOSE: Fractures of the tibial eminence can be treated arthroscopically. Fixation of the fracture is usually followed by temporary immobilization. The literature suggests that only anterograde fixation with cannulated screws and washer is considered stable enough to allow for immediate mobilization and weight bearing. The goal of this study was to evaluate the 5-year results of arthroscopic reductions and anterograde fixations of the tibial eminence fracture with cannulated screws. TYPE OF STUDY: Retrospective study.
METHODS: Thirty-two patients were treated arthroscopically for type II, III, and IV fractures of the intercondylar eminence of the tibia. The fragments were reduced and fixed with a cannulated screw or cannulated screw and washer. The intermeniscal ligament was involved in the fracture in 29 cases, and the anterior part of the medial meniscus was involved in 3 cases, requiring a temporary shift before reduction of the fragment. Arthrotomy was not performed for reduction or fixation of the fragment. All patients began continuous passive and active motion of the involved knee and were mobilized on crutches the day after the procedure. They were allowed immediate weight bearing. The patients were followed up for 16 to 69 months.
RESULTS: Good therapeutic results were found at follow-up. Average value for KT-1000 testing was 1.1 mm; flexion deficit was 1.2 degrees; extension deficit, 0.6 degrees; and Lysholm score, 98.8. The average treatment duration was 12 weeks. There was one case of aseptic synovitis and no other complications. In all but 1 patient, the implants were removed.
CONCLUSIONS: Arthroscopic fixation of the fracture of the intercondylar eminence of the tibia with a cannulated screw or screw and washer is a simple, safe, reproducible, and effective procedure. The fixation is stable even in type IV fractures, so that immobilization is unnecessary.

Entities:  

Mesh:

Year:  2003        PMID: 12522403     DOI: 10.1053/jars.2003.50012

Source DB:  PubMed          Journal:  Arthroscopy        ISSN: 0749-8063            Impact factor:   4.772


  24 in total

1.  Biomechanical comparison of three techniques for fixation of tibial avulsion fractures of the anterior cruciate ligament.

Authors:  Yong In; Dai-Soon Kwak; Chan-Woong Moon; Seung-Ho Han; Nam-Yong Choi
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-10-11       Impact factor: 4.342

2.  Absorbable and non-absorbable suture fixation results in similar outcomes for tibial eminence fractures in children and adolescents.

Authors:  Stefan Brunner; Patrick Vavken; Robert Kilger; Julia Vavken; Erich Rutz; Reinald Brunner; Carlo Camathias
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2015-10-31       Impact factor: 4.342

3.  Arthroscopic fixation of anterior cruciate ligament tibial avulsion fractures using bioabsorbable suture anchors.

Authors:  Yong In; Jung-Man Kim; Young-Kyun Woo; Nam-Yong Choi; Chan-Woong Moon; Min-Woo Kim
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2007-12-22       Impact factor: 4.342

4.  Physeal sparing arthroscopic fixation of displaced tibial eminence fractures: a new surgical technique.

Authors:  Michael T Hirschmann; Ralph R Mayer; Axel Kentsch; Niklaus F Friederich
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2009-02-19       Impact factor: 4.342

5.  [Biodegradable screw versus a press-fit bone plug fixation for ACL reconstruction: a prospective randomized study].

Authors:  B Geiges; C von Falck; K Knobloch; C Haasper; R Meller; C Krettek; S Hankemeier; J Brand; M Jagodzinski
Journal:  Unfallchirurg       Date:  2013-02       Impact factor: 1.000

6.  ORV Arthroscopic Reduction and Internal Fixation of Tibial Eminence Fractures.

Authors:  Daniel M Myer; Gregory J Purnell; Paul E Caldwell; Sara E Pearson
Journal:  Arthrosc Tech       Date:  2013-09-13

7.  Relation of discoid lateral meniscus and cord-like anterior intermeniscal ligament: morphological and clinical study.

Authors:  Haluk Ozcanli; Nigar Keles; Nüket Gocmen-Mas; Alpay Merter Ozenci; Ahmet Turan Aydin
Journal:  Surg Radiol Anat       Date:  2011-03-15       Impact factor: 1.246

8.  Bioabsorbable sutures versus screw fixation of displaced tibial eminence fractures: a biomechanical study.

Authors:  Vladimir Senekovic; Matej Balazic
Journal:  Eur J Orthop Surg Traumatol       Date:  2013-02-09

9.  Pediatric ACL injuries: evaluation and management.

Authors:  Nathan A Mall; George A Paletta
Journal:  Curr Rev Musculoskelet Med       Date:  2013-06

10.  [Pediatric knee injuries].

Authors:  F Schneider; M Sperl; G Steinwender; T Kraus
Journal:  Orthopade       Date:  2014-04       Impact factor: 1.087

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.