Literature DB >> 12520672

Upgrade of permanent pacemakers and single chamber implantable cardioverter defibrillators to pectoral dual chamber implantable cardioverter defibrillators: indications, surgical approach, and long-term clinical results.

Michael O Sweeney1, Julie B Shea, Kristin E Ellison.   

Abstract

The aim of this study was to describe the indications for upgrade of pacemakers (PMs) or single chamber (VVIR) ICDs to dual chamber (DDDR) ICDs, surgical approach, hardware hybridization, and clinical outcome. Patients with preexisting PMs or VVIR ICDs may develop indications for ICD therapy or dual chamber pacing, respectively, that can be served by DDDR ICDs that incorporate preexisting transvenous leads. Fifty-seven patients underwent upgrade from PMs (29/57) or VVIR ICDs (28/57) to pectoral DDDR ICDs. Preexisting transvenous atrial and/or ventricular leads suitable for continued use were incorporated into new DDDR ICDs in 88.5% and 100% of PM and VVIR ICD upgrades, respectively. Acceptable DFTs were achieved in 56 (98.2%) of 57 patients. Appropriate VT/VF therapies were registered among 33.3% of patients during follow-up. No shocks due to lead noise were observed in any patient with hybridized transvenous leads. Atrial far-field R wave (FFRW) oversensing occurred in 24% of DDDR ICD systems incorporating a preexisting atrial lead. FFRW was overcome by programming reduced atrial sensitivity without interfering with the normal ICD system performance in all instances. Upgrade of PMs and VVIR ICDs to pectoral DDDR ICDs is safe and technically feasible in most patients. Preexisting transvenous leads can be successfully incorporated into new DDDR ICDs, simplifying the surgical procedure, minimizing transvenous hardware, and eliminating the possibility of hazardous pacemaker-ICD interactions.

Entities:  

Mesh:

Year:  2002        PMID: 12520672     DOI: 10.1046/j.1460-9592.2002.01715.x

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  2 in total

Review 1.  A Questionable Indication For ICD Extraction After Successful VT Ablation.

Authors:  Luca Segreti; Andrea Di Cori; Giulio Zucchelli; Ezio Soldati; Giovanni Coluccia; Stefano Viani; Luca Paperini; Maria Grazia Bongiorni
Journal:  J Atr Fibrillation       Date:  2015-04-30

2.  Cardiac device implantation in the United States from 1997 through 2004: a population-based analysis.

Authors:  Chunliu Zhan; William B Baine; Artyom Sedrakyan; Claudia Steiner
Journal:  J Gen Intern Med       Date:  2008-01       Impact factor: 5.128

  2 in total