Literature DB >> 12518952

Cephalometric and in vivo measurements of maxillomandibular anteroposterior discrepancies: a preliminary regression study.

Virgilio Ferruccio Ferrario1, Graziano Serrao, Veronica Ciusa, Maria Morini, Chiarella Sforza.   

Abstract

One of the aims of the present investigation was to assess three-dimensionally the anteroposterior discrepancy of dental bases using a noninvasive direct procedure. A second aim was to verify the relationship of three-dimensional soft-tissue measurement to the well-established two-dimensional cephalometric assessments of anteroposterior discrepancy. Dental and facial landmarks were directly digitized on 20 orthodontic and maxillofacial surgery patients aged 8 to 26 years using an electromagnetic three-dimensional computerized digitizer. The anteroposterior maxillomandibular discrepancy was measured by calculating the linear distances between the projections of subnasal and sublabial landmarks on the occlusal plane, subnasal and sublabial landmarks on Camper's plane, and insertion of maxillary and mandibular median labial frenula on the occlusal plane. From lateral cephalograms of the same patients, the following measurements were obtained: subspinale point-nasion-supramentale point (ANB) angle; corrected ANB angle that compensates for the position of the maxilla and rotation of the mandible relative to the cranial base; Wits appraisal; MM-Wits, linear distance between the projections of points A and B on the bisector of the palatal plane to mandibular plane angle; and soft-tissue Wits, linear distance between the projections of soft-tissue points A and B on the bisecting occlusal plane. The best two-dimensional vs three-dimensional linear regression (r = 0.91) was found between Wits appraisal and the linear distances between the projections of maxillary and mandibular median labial frenula on the occlusal plane (Wits = -1.05 x 3D measurement - 3.75). The three-dimensional evaluation of the sagittal discrepancy of the jaws directly performed in vivo may allow a more complete analysis of a patient's soft-tissue drape together with the underlying hard-tissue structure.

Entities:  

Mesh:

Year:  2002        PMID: 12518952     DOI: 10.1043/0003-3219(2002)072<0579:CAIVMO>2.0.CO;2

Source DB:  PubMed          Journal:  Angle Orthod        ISSN: 0003-3219            Impact factor:   2.079


  3 in total

1.  Cephalometric Variables Prediction from Lateral Photographs Between Different Skeletal Patterns Using Regression Artificial Neural Networks.

Authors:  Saif Mauwafak Ali; Hayder Fadhil Saloom; Mohammed Ali Tawfeeq
Journal:  Turk J Orthod       Date:  2022-06

2.  The occlusal plane in the facial context: inter-operator repeatability of a new three-dimensional method.

Authors:  Riccardo Rosati; Alberto Rossetti; Marcio De Menezes; Virgilio F Ferrario; Chiarella Sforza
Journal:  Int J Oral Sci       Date:  2012-01-12       Impact factor: 6.344

3.  Photographic assessment of cephalometric measurements.

Authors:  Liliane de Carvalho Rosas Gomes; Karla Orfelina Carpio Horta; Luiz Gonzaga Gandini; Marcelo Gonçalves; João Roberto Gonçalves
Journal:  Angle Orthod       Date:  2013-04-18       Impact factor: 2.079

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.