Literature DB >> 12517018

Prevention of bloodstream infections with central venous catheters treated with anti-infective agents depends on catheter type and insertion time: evidence from a meta-analysis.

Bernhard Walder1, Didier Pittet, Martin R Tramèr.   

Abstract

OBJECTIVE: To test the evidence that the risk of infection related to central venous catheters (CVCs) is decreased by anti-infective coating or cuffing.
DESIGN: Systematic review of randomized, controlled trials comparing anti-infective with inactive (control) CVCs.
INTERVENTIONS: Average insertion times were taken as a measurement of the length of insertion. Dichotomous data were combined using a fixed effect model and expressed as odds ratio (OR) with 95% confidence interval (CI95).
RESULTS: Two trials on antibiotic coating (343 CVCs) had an average insertion time of 6 days; the risk of BSI decreased from 5.1% with control to 0% with anti-infective catheters. There were no trials with longer average insertion times. In three trials on silver collagen cuffs (422 CVCs), the average insertion time ranged from 5 to 8.2 days (median, 7 days); the risk of BSI was 5.6% with control and 3.2% with anti-infective catheters. In another trial on silver collagen cuffs (101 CVCs), the average insertion time was 38 days; the risk of BSI was 3.7% with control and 4.3% with anti-infective catheters. In five trials on chlorhexidine-silver sulfadiazine coating (1,269 CVCs), the average insertion time ranged from 5.2 to 7.5 days (median, 6 days); the risk of BSI decreased from 4.1% with control to 1.9% with anti-infective catheters. In five additional trials on chlorhexidine-silver sulfadiazine coating (1,544 CVCs), the average insertion time ranged from 7.8 to 20 days (median, 12 days); the risk of BSI was 4.5% with control and 4.2% with anti-infective catheters.
CONCLUSIONS: Antibiotic and chlorhexidine-silver sulfadiazine coatings are anti-infective for short (approximately 1 week) insertion times. For longer insertion times, there are no data on antibiotic coating, and there is evidence of lack of effect for chlorhexidine-silver sulfadiazine coating. For silver-impregnated collagen cuffs, there is evidence of lack of effect for both short- and long-term insertion.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12517018     DOI: 10.1086/502005

Source DB:  PubMed          Journal:  Infect Control Hosp Epidemiol        ISSN: 0899-823X            Impact factor:   3.254


  24 in total

Review 1.  [Meta-analysis. A meaningful tool for evidence-based (intensive) medicine].

Authors:  M R Tramèr
Journal:  Anaesthesist       Date:  2003-12       Impact factor: 1.041

2.  Number needed to treat (or harm).

Authors:  Martin R Tramèr; Bernhard Walder
Journal:  World J Surg       Date:  2005-05       Impact factor: 3.352

Review 3.  Anti-infective-treated central venous catheters: a systematic review of randomized controlled trials.

Authors:  B S Niël-Weise; T Stijnen; P J van den Broek
Journal:  Intensive Care Med       Date:  2007-10-17       Impact factor: 17.440

4.  In Vitro and In Vivo Effectiveness of an Innovative Silver-Copper Nanoparticle Coating of Catheters To Prevent Methicillin-Resistant Staphylococcus aureus Infection.

Authors:  Myriam K S Ballo; Sami Rtimi; César Pulgarin; Nancy Hopf; Aurélie Berthet; John Kiwi; Philippe Moreillon; José M Entenza; Alain Bizzini
Journal:  Antimicrob Agents Chemother       Date:  2016-08-22       Impact factor: 5.191

5.  Comparison of antimicrobial impregnation with tunneling of long-term central venous catheters: a randomized controlled trial.

Authors:  Rabih O Darouiche; David H Berger; Nancy Khardori; Claudia S Robertson; Matthew J Wall; Michael H Metzler; Seema Shah; Mohammad D Mansouri; Colleen Cerra-Stewart; James Versalovic; Michael J Reardon; Issam I Raad
Journal:  Ann Surg       Date:  2005-08       Impact factor: 12.969

6.  epic3: national evidence-based guidelines for preventing healthcare-associated infections in NHS hospitals in England.

Authors:  H P Loveday; J A Wilson; R J Pratt; M Golsorkhi; A Tingle; A Bak; J Browne; J Prieto; M Wilcox
Journal:  J Hosp Infect       Date:  2014-01       Impact factor: 3.926

Review 7.  Pseudomonas aeruginosa, Candida albicans, and device-related nosocomial infections: implications, trends, and potential approaches for control.

Authors:  George E Pierce
Journal:  J Ind Microbiol Biotechnol       Date:  2005-05-03       Impact factor: 3.346

8.  [Prevention and follow-up care of sepsis. 1st revision of S2k guidelines of the German Sepsis Society (Deutsche Sepsis-Gesellschaft e.V., DSG) and the German Interdisciplinary Association of Intensive Care and Emergency Medicine (Deutsche Interdisziplinäre Vereinigung für Intensiv- und Notfallmedizin, DIVI)].

Authors:  F M Brunkhorst; P Gastmeier; W Kern; W Krüger; K Mayer; A Weimann; T Welte; C Putensen; K Werdan; K Reinhart
Journal:  Internist (Berl)       Date:  2010-07       Impact factor: 0.743

9.  Prevention, diagnosis, therapy and follow-up care of sepsis: 1st revision of S-2k guidelines of the German Sepsis Society (Deutsche Sepsis-Gesellschaft e.V. (DSG)) and the German Interdisciplinary Association of Intensive Care and Emergency Medicine (Deutsche Interdisziplinäre Vereinigung für Intensiv- und Notfallmedizin (DIVI)).

Authors:  K Reinhart; F M Brunkhorst; H-G Bone; J Bardutzky; C-E Dempfle; H Forst; P Gastmeier; H Gerlach; M Gründling; S John; W Kern; G Kreymann; W Krüger; P Kujath; G Marggraf; J Martin; K Mayer; A Meier-Hellmann; M Oppert; C Putensen; M Quintel; M Ragaller; R Rossaint; H Seifert; C Spies; F Stüber; N Weiler; A Weimann; K Werdan; T Welte
Journal:  Ger Med Sci       Date:  2010-06-28

Review 10.  Nanomaterials and synergistic low-intensity direct current (LIDC) stimulation technology for orthopedic implantable medical devices.

Authors:  Rohan A Shirwaiker; Meghan E Samberg; Paul H Cohen; Richard A Wysk; Nancy A Monteiro-Riviere
Journal:  Wiley Interdiscip Rev Nanomed Nanobiotechnol       Date:  2013-01-17
View more