Literature DB >> 12515744

Intravascular ultrasound guidance improves angiographic and clinical outcome of stent implantation for long coronary artery stenoses: final results of a randomized comparison with angiographic guidance (TULIP Study).

Pranobe V Oemrawsingh1, Gary S Mintz, Martin J Schalij, Aeilko H Zwinderman, J Wouter Jukema, Ernst E van der Wall.   

Abstract

BACKGROUND: Long coronary lesions treated with stents have a poor outcome. This study compared the 6-month outcome of stent implantation for long lesions in patients randomized to intravascular ultrasound (IVUS; n=73) or angiographic guidance (n=71). METHODS AND
RESULTS: Stenoses >20 mm in length and a reference diameter that permitted a stent diameter > or =3 mm were eligible. Primary end points were 6-month minimal lumen diameter (MLD) and the combined end point of death, myocardial infarction, and target-lesion revascularization (TLR). Baseline clinical and angiographic data were comparable in both groups. At 6 months, MLD in the IVUS group (1.82+/-0.53 mm) was larger than in the angiography group (1.51+/-0.71 mm; P=0.042). TLR and combined end-point rates at 6 months were 4% (n=3) and 6% (n=4) in the IVUS group and 14% (n=10) and 20% (n=14) in the angiography group, respectively (P=0.037 for TLR and P=0.01 for combined events). Restenosis (>50% diameter stenosis) was found in 23% of the IVUS group and 45% of the angiography group (P=0.008). At 12 months, TLR and the combined end point occurred in 10% (n=7) and 12% (n=9) of the IVUS group and 23% (n=17) and 27% (n=19) of the angiography group (P=0.018 and P=0.026), respectively.
CONCLUSIONS: Angiographic and clinical outcome up to 12 months after long stent placement guided by IVUS is superior to guidance by angiography.

Entities:  

Mesh:

Year:  2003        PMID: 12515744     DOI: 10.1161/01.cir.0000043240.87526.3f

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  48 in total

Review 1.  New imaging techniques for diagnosing coronary artery disease.

Authors:  Esteban Escolar; Guy Weigold; Anthon Fuisz; Neil J Weissman
Journal:  CMAJ       Date:  2006-02-14       Impact factor: 8.262

Review 2.  Causes, assessment, and treatment of stent thrombosis--intravascular imaging insights.

Authors:  Daniel S Ong; Ik-Kyung Jang
Journal:  Nat Rev Cardiol       Date:  2015-03-17       Impact factor: 32.419

3.  Optical coherence tomography- vs. intravascular ultrasound-guided percutaneous coronary intervention.

Authors:  Lorenz Räber; Yasushi Ueki
Journal:  J Thorac Dis       Date:  2017-06       Impact factor: 2.895

4.  Progress in atherosclerotic plaque imaging.

Authors:  Giulia Soloperto; Sergio Casciaro
Journal:  World J Radiol       Date:  2012-08-28

5.  Feasibility of using intravascular ultrasonography for assessment of giant cavernous aneurysm after endovascular treatment: a technical report.

Authors:  Shahram Majidi; Mikayel Grigoryan; Wondwossen G Tekle; Masaki Watanabe; Adnan I Qureshi
Journal:  J Vasc Interv Neurol       Date:  2012-06

6.  The 5352 A allele of the pro-inflammatory caspase-1 gene predicts late-acquired stent malapposition in STEMI patients treated with sirolimus stents.

Authors:  Sandrin C Bergheanu; Douwe Pons; Bas L van der Hoeven; Su-San Liem; Bob Siegerink; Martin J Schalij; Johanna G van der Bom; J Wouter Jukema
Journal:  Heart Vessels       Date:  2010-10-30       Impact factor: 2.037

Review 7.  The Role of Intracoronary Plaque Imaging with Intravascular Ultrasound, Optical Coherence Tomography, and Near-Infrared Spectroscopy in Patients with Coronary Artery Disease.

Authors:  Vu Hoang; Jill Grounds; Don Pham; Salim Virani; Ihab Hamzeh; Athar Mahmood Qureshi; Nasser Lakkis; Mahboob Alam
Journal:  Curr Atheroscler Rep       Date:  2016-09       Impact factor: 5.113

8.  Impact of StentBoost subtract imaging on patient radiation exposure during percutaneous coronary intervention.

Authors:  Zhigeng Jin; Shengli Yang; Limin Jing; Huiliang Liu
Journal:  Int J Cardiovasc Imaging       Date:  2013-03-03       Impact factor: 2.357

9.  IVUS-Guided Stent Implantation to Improve Outcome: A Promise Waiting to be Fulfilled.

Authors:  Renata Rogacka; Azeem Latib; Antonio Colombo
Journal:  Curr Cardiol Rev       Date:  2009-05

10.  Intravascular ultrasound to guide percutaneous coronary interventions: an evidence-based analysis.

Authors: 
Journal:  Ont Health Technol Assess Ser       Date:  2006-04-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.