BACKGROUND: We have previously reported the safety and effectiveness of sirolimus-eluting stents for the treatment of de novo coronary lesions. The present investigation explored the potential of this technology to treat in-stent restenosis. METHODS AND RESULTS: Twenty-five patients with in-stent restenosis were successfully treated with the implantation of 1 or 2 sirolimus-eluting Bx VELOCITY stents in São Paulo, Brazil. Nine patients received 2 stents (1.4 stents per lesion). Angiographic and volumetric intravascular ultrasound (IVUS) images were obtained after the procedure and at 4 and 12 months. All vessels were patent at the time of 12-month angiography. Angiographic late loss averaged 0.07+/-0.2 mm in-stent and -0.05+/-0.3 mm in-lesion at 4 months, and 0.36+/-0.46 mm in-stent and 0.16+/-0.42 mm in-lesion after 12 months. No patient had in-stent or stent margin restenosis at 4 months, and only one patient developed in-stent restenosis at 1-year follow-up. Intimal hyperplasia by 3-dimensional IVUS was 0.92+/-1.9 mm(3) at 4 months and 2.55+/-4.9 mm(3) after 1 year. Percent volume obstruction was 0.81+/-1.7% and 1.76+/-3.4% at the 4- and 12-month follow-up, respectively. There was no evidence of stent malapposition either acutely or in the follow-up IVUS images, and there were no deaths, stent thromboses, or repeat revascularizations. CONCLUSION: This study demonstrates the safety and the potential utility of sirolimus-eluting Bx VELOCITY stents for the treatment of in-stent restenosis.
BACKGROUND: We have previously reported the safety and effectiveness of sirolimus-eluting stents for the treatment of de novo coronary lesions. The present investigation explored the potential of this technology to treat in-stent restenosis. METHODS AND RESULTS: Twenty-five patients with in-stent restenosis were successfully treated with the implantation of 1 or 2 sirolimus-eluting Bx VELOCITY stents in São Paulo, Brazil. Nine patients received 2 stents (1.4 stents per lesion). Angiographic and volumetric intravascular ultrasound (IVUS) images were obtained after the procedure and at 4 and 12 months. All vessels were patent at the time of 12-month angiography. Angiographic late loss averaged 0.07+/-0.2 mm in-stent and -0.05+/-0.3 mm in-lesion at 4 months, and 0.36+/-0.46 mm in-stent and 0.16+/-0.42 mm in-lesion after 12 months. No patient had in-stent or stent margin restenosis at 4 months, and only one patient developed in-stent restenosis at 1-year follow-up. Intimal hyperplasia by 3-dimensional IVUS was 0.92+/-1.9 mm(3) at 4 months and 2.55+/-4.9 mm(3) after 1 year. Percent volume obstruction was 0.81+/-1.7% and 1.76+/-3.4% at the 4- and 12-month follow-up, respectively. There was no evidence of stent malapposition either acutely or in the follow-up IVUS images, and there were no deaths, stent thromboses, or repeat revascularizations. CONCLUSION: This study demonstrates the safety and the potential utility of sirolimus-eluting Bx VELOCITY stents for the treatment of in-stent restenosis.
Authors: Jawad F Kirmani; Nazli Janjua; Ammar Al Kawi; Shafiuddin Ahmed; Ismail Khatri; Ali Ebrahimi; Afshin A Divani; Adnan I Qureshi Journal: NeuroRx Date: 2005-04
Authors: Ralf Zahn; C W Hamm; S Schneider; U Zeymer; G Richardt; M Kelm; B Levenson; T Bonzel; U Tebbe; G Sabin; C A Nienaber; Thomas Pfannebecker; J Senges Journal: Clin Res Cardiol Date: 2007-06-04 Impact factor: 5.460
Authors: Helge Möllmann; Albrecht Elsässer; Holger Nef; Steffen Schneider; Christoph A Nienaber; Gert Richardt; Michael Weber; Malte Kelm; Benny Levenson; Tassilo Bonzel; Ulrich Tebbe; Georg Sabin; Thomas Pfannebecker; Jochen Senges; Christian W Hamm Journal: Clin Res Cardiol Date: 2008-03-03 Impact factor: 5.460
Authors: Kevin W Southerland; Sarah B Frazier; Dawn E Bowles; Carmelo A Milano; Christopher D Kontos Journal: Transl Res Date: 2012-12-27 Impact factor: 7.012
Authors: Ralf Zahn; Christian W Hamm; Uwe Zeymer; Gert Richardt; Malte Kelm; Benny Levenson; Tassilo Bonzel; Ulrich Tebbe; Georg Sabin; Christoph A Nienaber; Thomas Pfannebecker; Jochen Senges Journal: Clin Res Cardiol Date: 2009-10-31 Impact factor: 5.460