Literature DB >> 12515502

G-quadruplex formation of thrombin-binding aptamer detected by electrospray ionization mass spectrometry.

M Vairamani1, Michael L Gross.   

Abstract

Electrospray ionization mass spectrometry detected the formation of the G-quadruplex structure of the thrombin-binding aptamer, d(GGTTGGTGTGGTTGG), and established its specific interaction with metal ions. One piece of evidence that the bonding in the gas phase is via the G-quadruplex form is the enhanced binding, with respect to other metal ions, of the aptamer with Sr2+, Pb2+, Ba2+, and K+, which are of similar size. Another is the lack of specific binding with controls in which the G's are replaced with A's. The most convincing evidence is the extent of H/D exchange of the gas-phase aptamer as compared to that bound to K+ and Sr2+. The latter two complexes exchange six and nine fewer H's, indicating a significant increase in protection upon binding to the metals. Mass spectrometry will be an important tool in understanding G-quadruplexes, which are particularly important in DNA telomers.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12515502     DOI: 10.1021/ja0284299

Source DB:  PubMed          Journal:  J Am Chem Soc        ISSN: 0002-7863            Impact factor:   15.419


  26 in total

1.  Mass spectrometric studies of alkali metal ion binding on thrombin-binding aptamer DNA.

Authors:  Eun Sun Hong; Hye-Joo Yoon; Byungjoo Kim; Yong-Hyeon Yim; Hun-Young So; Seung Koo Shin
Journal:  J Am Soc Mass Spectrom       Date:  2010-04-02       Impact factor: 3.109

2.  Bimolecular quadruplexes and their transitions to higher-order molecular structures detected by ESI-FTICR-MS.

Authors:  Xinhua Guo; Shuying Liu; Zhan Yu
Journal:  J Am Soc Mass Spectrom       Date:  2007-05-10       Impact factor: 3.109

3.  Investigation of formation, recognition, stabilization, and conversion of dimeric G-quadruplexes of HIV-1 integrase inhibitors by electrospray ionization mass spectrometry.

Authors:  Huihui Li; Gu Yuan; Daming Du
Journal:  J Am Soc Mass Spectrom       Date:  2008-02-05       Impact factor: 3.109

4.  ESI-MS characterization of a novel pyrrole-inosine nucleoside that interacts with guanine bases.

Authors:  Sarah E Pierce; Courtney L Sherman; Janarthanan Jayawickramarajah; Candace M Lawrence; Jonathan L Sessler; Jennifer S Brodbelt
Journal:  Anal Chim Acta       Date:  2008-04-15       Impact factor: 6.558

5.  Encapsulating a single G-quadruplex aptamer in a protein nanocavity.

Authors:  Ji Wook Shim; Li-Qun Gu
Journal:  J Phys Chem B       Date:  2008-06-19       Impact factor: 2.991

6.  A highly Sensitive Turn-on Fluorescent Sensor for Ba2+ Based on G-Quadruplexes.

Authors:  Lijun Xu; Yang Chen; Ruihua Zhang; Tian Gao; Yajie Zhang; Xiaoqiang Shen; Renjun Pei
Journal:  J Fluoresc       Date:  2016-11-18       Impact factor: 2.217

7.  Structural Characterization of a Thrombin-Aptamer Complex by High Resolution Native Top-Down Mass Spectrometry.

Authors:  Jiang Zhang; Rachel R Ogorzalek Loo; Joseph A Loo
Journal:  J Am Soc Mass Spectrom       Date:  2017-07-28       Impact factor: 3.109

8.  Evaluation of effects of bivalent cations on the formation of purine-rich triple-helix DNA by ESI-FT-MS.

Authors:  Cuihong Wan; Meng Cui; Fengrui Song; Zhiqiang Liu; Shuying Liu
Journal:  J Am Soc Mass Spectrom       Date:  2009-02-25       Impact factor: 3.109

9.  Interaction between cationic zinc porphyrin and lead ion induced telomeric guanine quadruplexes: evidence for end-stacking.

Authors:  Jingxi Pan; Suping Zhang
Journal:  J Biol Inorg Chem       Date:  2008-12-02       Impact factor: 3.358

10.  Highly sensitive optical biosensor for thrombin based on structure switching aptamer-luminescent silica nanoparticles.

Authors:  Ethiraju Babu; Paulpandian Muthu Mareeswaran; Seenivasan Rajagopal
Journal:  J Fluoresc       Date:  2012-09-11       Impact factor: 2.217

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.