Literature DB >> 12514634

Anatomic three-dimensional echocardiographic correlation of bicuspid aortic valve.

Nilda Espinola-Zavaleta1, Luis Muñoz-Castellanos, Fause Attié, Gunther Hernández-Morales, Carlos Zamora-González, Roy Dueñas-Carbajal, Nuria Granados, Candace Keirns, Jesús Vargas-Barrón.   

Abstract

This study was undertaken to verify the echocardiographic characteristics of bicuspid aortic valve (AV) using 3-dimensional transesophageal echocardiography by comparing the findings with anatomic examination of autopsy specimens from carriers of this condition. Three-dimensional reconstructions of transesophageal echocardiograms were performed on 14 patients with bicuspid AV, and 20 autopsy specimens of bicuspid AVs were analyzed. Echocardiographic images and autopsy material were correlated. Two variants of bicuspid aorta were identified. In group I the AV had 2 leaflets. This group included 9 (9/14) 3-dimensional echocardiographic studies and 13 (13/20) necropsies. In group II 3 sigmoid leaflets had originally developed and 2 underwent dysplastic fusion, resulting in functionally bicuspid valves. Five (5/14) echocardiographic studies and 7 (7/20) anatomic specimens fell into this category. There was a clear correspondence between anatomic and echocardiographic findings, which leads to the conclusion that 3-dimensional echocardiography is a technique that reliably defines the morphological details of bicuspid AV with the precision of anatomopathologic examination.

Entities:  

Mesh:

Year:  2003        PMID: 12514634     DOI: 10.1067/mje.2003.30

Source DB:  PubMed          Journal:  J Am Soc Echocardiogr        ISSN: 0894-7317            Impact factor:   5.251


  6 in total

1.  Individualized thoracic aortic replacement for the aortopathy of biscuspid aortic valve disease.

Authors:  Brian Lima; Judson B Williams; S Dave Bhattacharya; Asad A Shah; Nicholas Andersen; Andrew Wang; J Kevin Harrison; G Chad Hughes
Journal:  J Heart Valve Dis       Date:  2011-07

2.  Diagnostic accuracy study of routine echocardiography for bicuspid aortic valve: a retrospective study and meta-analysis.

Authors:  Mathias Hillebrand; Dietmar Koschyk; Pia Ter Hark; Helke Schüler; Meike Rybczynski; Jürgen Berger; Amit Gulati; Alexander M Bernhardt; Christian Detter; Evaldas Girdauskas; Stefan Blankenberg; Yskert von Kodolitsch
Journal:  Cardiovasc Diagn Ther       Date:  2017-08

3.  Aortic obstruction: anatomy and echocardiography.

Authors:  Nilda Espinola-Zavaleta; Luis Muñoz-Castellanos; Magdalena Kuri-Nivon; Candace Keirns
Journal:  Cardiovasc Ultrasound       Date:  2006-09-29       Impact factor: 2.062

4.  Application research of three-dimensional transesophageal echocardiography in predicting prosthetic valve size for transcatheter aortic valve implantation.

Authors:  Xin Meng; Yandan Sun; Wei Bai; Yuxi Li; Shengjun Tuo; Liang Cao; Mengmeng Du; Yang Liu; Ping Jin; Jian Yang; Liwen Liu
Journal:  Ann Transl Med       Date:  2022-01

5.  Percutaneous closure of interatrial communications in adults - prospective embolism prevention study with two- and three-dimensional echocardiography.

Authors:  Fabian Knebel; Volker Gliech; Torsten Walde; Alexander Panda; Wasiem Sanad; Stephan Eddicks; Gert Baumann; Adrian C Borges
Journal:  Cardiovasc Ultrasound       Date:  2004-05-19       Impact factor: 2.062

6.  Understanding atrioventricular septal defect: anatomoechocardiographic correlation.

Authors:  Nilda Espinola-Zavaleta; Luís Muñoz-Castellanos; Magdalena Kuri-Nivón; Candace Keirns
Journal:  Cardiovasc Ultrasound       Date:  2008-06-24       Impact factor: 2.062

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.