Literature DB >> 12514585

Conformational changes associated with proximal seal zone failure in abdominal aortic endografts.

Jose R Parra1, Juan Ayerdi, Robert McLafferty, Laura Gruneiro, Don Ramsey, Maurice Solis, Kim Hodgson.   

Abstract

OBJECTIVE: Endovascular aneurysm repair (EVAR) has become a popular treatment for abdominal aortic aneurysm (AAA). This study examines conformational changes in the infrarenal aortas of patients in whom proximal seal zone failures (PSF) developed after EVAR.
METHODS: All 189 patients with aortic endograft underwent routine post-EVAR computed tomographic scan surveillance. Patients identified with proximal type I endoleaks, type III endoleaks, or proximal component separation without demonstrable endoleak underwent three-dimensional reconstruction of the computed tomographic scans from which measurements of the migration, length, volume, and angulation of the infrarenal aorta were made.
RESULTS: Five patients (3%) had PSF develop, four of whom had aortic extender cuffs. Although changes in the AAA volume and aortic neck angle were slight or variable, the mean AAA length increased 34 mm and the mean aortic body angulation increased 17 degrees (P =.03 and.01, respectively). Lengthening and migration caused proximal component separation in four patients, with concomitant migration in two patients. Two patients underwent endovascular repair, two patients needed explantation of the endograft, and one patient awaits endovascular repair. Proximal component separation and type III endoleak recurred in one patient and were repaired with a custom-fitted graft.
CONCLUSION: PSF of aortic endografts is associated with proximal angulation and lengthening of the infrarenal aorta. These findings reinforce the importance of proper initial deployment to minimize the need for aortic extender cuffs, which pose a risk of late endoleak development.

Entities:  

Mesh:

Year:  2003        PMID: 12514585     DOI: 10.1067/mva.2002.53

Source DB:  PubMed          Journal:  J Vasc Surg        ISSN: 0741-5214            Impact factor:   4.268


  2 in total

1.  Effect of curvature on displacement forces acting on aortic endografts: a 3-dimensional computational analysis.

Authors:  C Alberto Figueroa; Charles A Taylor; Victoria Yeh; Allen J Chiou; Christopher K Zarins
Journal:  J Endovasc Ther       Date:  2009-06       Impact factor: 3.487

2.  Kilt Technique as an Angle Modification Method for Endovascular Repair of Abdominal Aortic Aneurysm with Severe Neck Angle.

Authors:  Tae-Hoon Kim; Ho-Jun Jang; Young Jin Choi; Chang Keun Lee; Sung Woo Kwon; Won-Heum Shim
Journal:  Ann Thorac Cardiovasc Surg       Date:  2017-03-23       Impact factor: 1.520

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.