Literature DB >> 12512990

Dental plaque removal efficacy of a battery-powered toothbrush vs. a control Japanese manual toothbrush.

Robert D Bartizek1, Aaron R Biesbrock.   

Abstract

PURPOSE: Recently, a new powered toothbrush has been marketed with a design that fundamentally differs from other marketed powered toothbrushes, in that it incorporates a round oscillating head, in conjunction with fixed bristles. The objective of this study was to compare the plaque removal efficacy of a control manual toothbrush (Lion Dentor Systema) to this experimental powered toothbrush (Crest SpinBrush) following a single use.
MATERIALS AND METHODS: This study was a randomized, controlled, examiner-blind, 4-period crossover design which examined plaque removal with the two toothbrushes following a single use in 36 subjects. Plaque was scored before and after brushing using the Turesky Modification of the Quigley-Hein Index.
RESULTS: Baseline plaque scores were 2.90 for the experimental toothbrush and 2.95 for the control toothbrush treatment groups. With respect to all surfaces examined, the experimental toothbrush delivered an adjusted (via analysis of covariance) mean difference between baseline and post-brushing plaque scores of 0.70 while the control toothbrush delivered an adjusted mean difference of 0.54. The difference between treatment groups was statistically significant (P < 0.001). The experimental toothbrush removed, on average, 29.6% more plaque than the control toothbrush. With respect to buccal surfaces, the experimental toothbrush delivered an adjusted mean difference between baseline and post-brushing plaque scores of 1.09 while the control toothbrush delivered an adjusted mean difference of 0.90. This difference between treatment groups was also statistically significant (P = 0.001) and represents, on average, 21.1% more plaque removal with the experimental toothbrush. Results on lingual surfaces also demonstrated statistically significantly (P< 0.001) greater plaque removal for the experimental toothbrush with an average of 83.3% more plaque removal.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12512990

Source DB:  PubMed          Journal:  Am J Dent        ISSN: 0894-8275            Impact factor:   1.522


  2 in total

Review 1.  Powered versus manual toothbrushing for oral health.

Authors:  Munirah Yaacob; Helen V Worthington; Scott A Deacon; Chris Deery; A Damien Walmsley; Peter G Robinson; Anne-Marie Glenny
Journal:  Cochrane Database Syst Rev       Date:  2014-06-17

2.  The Application Method of Nanobubble Conveyor on the Effect of Preventive Oral Hygiene.

Authors:  Pei-Ju Lin
Journal:  J Healthc Eng       Date:  2020-10-30       Impact factor: 2.682

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.