A CdZnTe slot-scanned detector for digital mammography.

James G Mainprize1, Nancy L Ford, Shi Yin, Eli E Gordon, William J Hamilton, Tümay O Tümer, Martin J Yaffe.   

Abstract

A new high-resolution detector has been developed for use in a slot-scanned digital mammography system. The detector is a hybrid device that consists of a CCD operating in time-delay integration mode that is bonded to a 150-microm-thick CdZnTe photoconductor array. The CCD was designed with a detector element pitch of 50 microm. Two devices were evaluated with differing crystalline quality. Incomplete charge collection was a source of reduction in DQE. This occurs in both devices due to characteristically low mobility-lifetime products for CdZnTe, with the greatest losses demonstrated by the multicrystalline sample. The mobility-lifetime products for the multicrystalline device were found to be 2.4 x 10(-4) and 4.0 x 10(-7) cm2/V for electrons and holes, respectively. The device constructed with higher quality single crystal CdZnTe demonstrated mobility-lifetime products of 1.0 x 10(-4) and 4.4 x 10(-6) cm2/V for electrons and holes. The MTF and DQE for the device were measured at several exposures and results were compared to predictions from a linear systems model of signal and noise propagation. The MTF at a spatial frequency of 10 mm(-1) exceeded 0.18 and 0.56 along the scan and slot directions, respectively. Scanning motion and CCD design limited the resolution along the scan direction. For an x-ray beam from a tungsten target tube with 40 microm molybdenum filtration operated at 26 kV, the single crystal device demonstrated a DQE(0) of 0.70 +/- 0.02 at 7.1 x 10(-6) C/kg (27 mR) exposure to the detector, despite its relatively poor charge collection efficiency.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12512710     DOI: 10.1118/1.1523932

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  4 in total

Review 1.  Digital detectors for mammography: the technical challenges.

Authors:  A Noel; F Thibault
Journal:  Eur Radiol       Date:  2004-10-08       Impact factor: 5.315

Review 2.  Breast cancer imaging: a perspective for the next decade.

Authors:  Andrew Karellas; Srinivasan Vedantham
Journal:  Med Phys       Date:  2008-11       Impact factor: 4.071

Review 3.  Amorphous and polycrystalline photoconductors for direct conversion flat panel x-ray image sensors.

Authors:  Safa Kasap; Joel B Frey; George Belev; Olivier Tousignant; Habib Mani; Jonathan Greenspan; Luc Laperriere; Oleksandr Bubon; Alla Reznik; Giovanni DeCrescenzo; Karim S Karim; John A Rowlands
Journal:  Sensors (Basel)       Date:  2011-05-09       Impact factor: 3.576

4.  Simulation and design of folded perovskite x-ray detectors.

Authors:  Henning Mescher; Elias Hamann; Uli Lemmer
Journal:  Sci Rep       Date:  2019-03-26       Impact factor: 4.379

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.