Literature DB >> 12509819

Comparison of the dependence of blood R2 and R2* on oxygen saturation at 1.5 and 4.7 Tesla.

M J Silvennoinen1, C S Clingman, X Golay, R A Kauppinen, P C M van Zijl.   

Abstract

Gradient-echo (GRE) blood oxygen level-dependent (BOLD) effects have both intra- and extravascular contributions. To better understand the intravascular contribution in quantitative terms, the spin-echo (SE) and GRE transverse relaxation rates, R(2) and R(2)(*), of isolated blood were measured as a function of oxygenation in a perfusion system. Over the normal oxygenation saturation range of blood between veins, capillaries, and arteries, the difference between these rates, R'(2) = R(2)(*) - R(2), ranged from 1.5 to 2.1 Hz at 1.5 T and from 26 to 36 Hz at 4.7 T. The blood data were used to calculate the expected intravascular BOLD effects for physiological oxygenation changes that are typical during visual activation. This modeling showed that intravascular DeltaR(2)(*) is caused mainly by R(2) relaxation changes, namely 85% and 78% at 1.5T and 4.7T, respectively. The simulations also show that at longer TEs (>70 ms), the intravascular contribution to the percentual BOLD change is smaller at high field than at low field, especially for GRE experiments. At shorter TE values, the opposite is the case. For pure parenchyma, the intravascular BOLD signal changes originate predominantly from venules for all TEs at low field and for short TEs at high field. At longer TEs at high field, the capillary contribution dominates. The possible influence of partial volume contributions with large vessels was also simulated, showing large (two- to threefold) increases in the total intravascular BOLD effect for both GRE and SE. Copyright 2003 Wiley-Liss, Inc.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12509819     DOI: 10.1002/mrm.10355

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  93 in total

1.  Blood longitudinal (T1) and transverse (T2) relaxation time constants at 11.7 Tesla.

Authors:  Ai-Ling Lin; Qin Qin; Xia Zhao; Timothy Q Duong
Journal:  MAGMA       Date:  2011-11-10       Impact factor: 2.310

2.  Contributions of dynamic venous blood volume versus oxygenation level changes to BOLD fMRI.

Authors:  Xiaopeng Zong; Tae Kim; Seong-Gi Kim
Journal:  Neuroimage       Date:  2012-02-28       Impact factor: 6.556

3.  Fast measurement of blood T1 in the human carotid artery at 3T: Accuracy, precision, and reproducibility.

Authors:  Wenbo Li; Peiying Liu; Hanzhang Lu; John J Strouse; Peter C M van Zijl; Qin Qin
Journal:  Magn Reson Med       Date:  2016-07-20       Impact factor: 4.668

4.  Advantages and pitfalls in 3T MR brain imaging: a pictorial review.

Authors:  Bernd L Schmitz; Andrik J Aschoff; Martin H K Hoffmann; Georg Grön
Journal:  AJNR Am J Neuroradiol       Date:  2005-10       Impact factor: 3.825

5.  T1rho contrast in functional magnetic resonance imaging.

Authors:  Justin Hulvershorn; Arijitt Borthakur; Luke Bloy; Eugene E Gualtieri; Ravinder Reddy; John S Leigh; Mark A Elliott
Journal:  Magn Reson Med       Date:  2005-11       Impact factor: 4.668

Review 6.  Whole-body MRI at high field: technical limits and clinical potential.

Authors:  Fritz Schick
Journal:  Eur Radiol       Date:  2005-01-27       Impact factor: 5.315

Review 7.  Prostate MR imaging at high-field strength: evolution or revolution?

Authors:  Olivier Rouvière; Robert P Hartman; Denis Lyonnet
Journal:  Eur Radiol       Date:  2005-09-10       Impact factor: 5.315

8.  Oxygen metabolism in ischemic stroke using magnetic resonance imaging.

Authors:  Hongyu An; Qingwei Liu; Yasheng Chen; Katie D Vo; Andria L Ford; Jin-Moo Lee; Weili Lin
Journal:  Transl Stroke Res       Date:  2011-12-13       Impact factor: 6.829

9.  Validation of oxygen extraction fraction measurement by qBOLD technique.

Authors:  Xiang He; Mingming Zhu; Dmitriy A Yablonskiy
Journal:  Magn Reson Med       Date:  2008-10       Impact factor: 4.668

10.  Quantitative evaluation of oxygenation in venous vessels using T2-Relaxation-Under-Spin-Tagging MRI.

Authors:  Hanzhang Lu; Yulin Ge
Journal:  Magn Reson Med       Date:  2008-08       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.