Literature DB >> 12505770

Determination of plasma topotecan and its metabolite N-desmethyl topotecan as both lactone and total form by reversed-phase liquid chromatography with fluorescence detection.

Feng Bai1, Mark N Kirstein, Suzan K Hanna, Lisa C Iacono, Brad Johnston, Clinton F Stewart.   

Abstract

Topotecan (TPT) undergoes hepatic N-demethylation forming N-desmethyl topotecan (NDS). To evaluate the effect of drug-drug interactions on NDS disposition in children receiving TPT we developed and validated a sensitive and specific HPLC-fluorescence detection method for lactone and total (lactone plus carboxylate) TPT and NDS. Deproteinized plasma is vortexed, centrifuged, and the methanolic extract diluted with water for the lactone form of NDS and TPT or diluted with 1.5% phosphoric acid for NDS and TPT total. A 100 microL sample is injected onto a Varian ChromGuard RP column attached to an Agilent SB-C(18) reversed-phase analytical column held at 50 degrees C. The mobile phase (flow-rate, 0.8 mL/min) consists of methanol-aqueous buffer (27:73, v/v) (75 mM potassium phosphate and 0.2% triethylamine, pH 6.5). TPT and NDS were detected with excitation and emission wavelengths set at 376 and 530 nm, respectively. The standard curves for both forms of TPT ranged from 0.25 to 80 ng/mL, and for NDS ranged from 0.10 to 8.0 ng/mL. Within-day and between-day precision (% RSD) was </=4% for TPT and </=6.2% for NDS, respectively. Within-day and between-day percentage error ranged from 1.4 to 6.3% and from 1.4 to 2.4% for TPT, and from 1.6 to 3.1% and from 0.0 to 3.7% for NDS, respectively. No significant on-column conversion from TPT or NDS lactone to carboxylate was observed. With one method we can measure lactone and total TPT and NDS with adequate sensitivity to allow for evaluation of the disposition of these compounds in children receiving TPT.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12505770     DOI: 10.1016/s1570-0232(02)00798-5

Source DB:  PubMed          Journal:  J Chromatogr B Analyt Technol Biomed Life Sci        ISSN: 1570-0232            Impact factor:   3.205


  3 in total

1.  Application of a highly specific and sensitive fluorescent HPLC method for topotecan lactone in whole blood.

Authors:  K Elaine Hubbard; Paula Schaiquevich; Feng Bai; Charles H Fraga; Laura Miller; John C Panetta; Clinton F Stewart
Journal:  Biomed Chromatogr       Date:  2009-07       Impact factor: 1.902

2.  Development and Validation of a RP-Ultra performance liquid chromatographic Method for Quantification of Topotecan Hydrochloride in Bulk and Injection Dosage Form.

Authors:  P K Saini; C L Jain; R M Singh; S C Mathur; G N Singh
Journal:  Indian J Pharm Sci       Date:  2010-07       Impact factor: 0.975

3.  Aqueous Solutions of Peptides and Trialkylamines Lead to Unexpected Peptide Modification.

Authors:  Yiran Ma; Puja J Gandhi; James P Reilly
Journal:  Molecules       Date:  2021-10-27       Impact factor: 4.411

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.