Literature DB >> 12504929

Assessing urinary albumin excretion in pre-eclamptic women: which sample to use?

Helle Kieler1, Tuttan Zettergren, Hanna Svensson, Paul W Dickman, Anders Larsson.   

Abstract

OBJECTIVE: To evaluate whether the gold standard of 24-hour urine collection for measuring albumin excretion in pre-eclamptic women could be substituted by shorter collection periods.
DESIGN: Prospective study.
SETTING: Fetal maternity ward, university hospital. PARTICIPANTS: Thirty women with pre-eclampsia and a positive urinary test strip for protein of at least 2+.
METHODS: From each woman, within a 25-hour period, three spot, two 12-hour (day and night) and one 24-hour urine sample were collected. Urine albumin concentrations in milligrammes per litre were analysed by rate nephelometry on a Beckman Array protein system. The urinary albumin concentrations in the spot and the 12-hour samples were compared with the concentration in the 24-hour urine collection. MAIN OUTCOME MEASURES: Urinary albumin concentrations in spot and 12-hour samples measured against the standard 24-hour albumin excretion.
RESULTS: Albumin concentrations in the day and night collection fitted closely with the concentrations of the 24-hour collection. The median difference between the 24-hour and the day collection was -3 mg/L (interquartile range -264 to 116 mg/L). The median difference between the 24-hour and the night collection was 17 mg/L (interquartile range -186 to 210 mg/L). The association of urinary albumin concentration in the 24-hour collection and the spot samples was much weaker. Of the spot urine samples, the albumin concentration in the sample taken on the morning after admission to hospital was closest to the 24-hour urinary albumin excretion, with a median difference of -62 mg/L (interquartile range -1131 to 285 mg/L).
CONCLUSION: The gold standard of 24-hour urinary excretion for assessment of albuminuria in pre-eclamptic women can be substituted with a 12-hour collection. Spot urine samples were inaccurate and are therefore not recommended for quantification of albumin excretion.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12504929

Source DB:  PubMed          Journal:  BJOG        ISSN: 1470-0328            Impact factor:   6.531


  3 in total

Review 1.  Diagnostic accuracy of urinary spot protein:creatinine ratio for proteinuria in hypertensive pregnant women: systematic review.

Authors:  Anne-Marie Côté; Mark A Brown; Elaine Lam; Peter von Dadelszen; Tabassum Firoz; Robert M Liston; Laura A Magee
Journal:  BMJ       Date:  2008-04-10

2.  Correlation of 2 hour, 4 hour, 8 hour and 12 hour urine protein with 24 hour urinary protein in preeclampsia.

Authors:  Savita Rani Singhal; Veena Ghalaut; Shashi Lata; Himanshu Madaan; Veenu Kadian; Ashuma Sachdeva
Journal:  J Family Reprod Health       Date:  2014-09

3.  Characterizing exposures to nonpersistent pesticides during pregnancy and early childhood in the National Children's Study: a review of monitoring and measurement methodologies.

Authors:  Asa Bradman; Robin M Whyatt
Journal:  Environ Health Perspect       Date:  2005-08       Impact factor: 9.031

  3 in total