Literature DB >> 12504198

Simultaneous determination of irbesartan and hydrochlorothiazide in human plasma by liquid chromatography.

Nevin Erk1.   

Abstract

A simple, selective, sensitive and precise high-performance liquid chromatographic plasma assay for the antihypertensive drugs, irbesartan and hydrochlorothiazide is described. Good chromatographic separation was achieved using a Supelcocil C(18) (5 micrometer 15 cmx4.6 mm) column and a mobile phase consisting of 10 mM potassium dihydrogen phosphate:methanol:acetonitrile (5:80:15 v/v/v) (pH:2.5) while at a flow-rate of 1.0 ml min(-1). Irbesartan and hydrochlorothiazide were detected at 275 nm and were eluted 5.8 and 7.8 min, respectively, after injection. No endogenous substances were found to interfere. The method utilizes protein precipitation with acetonitrile as the only sample preparation involved prior to reversed-phase high-performance liquid chromatography. No internal standard was required. Linearity range for irbesartan and hydrochlorothiazide was 10.0-60.0 microgram ml(-1) and 4.0-20.0 microgram ml(-1), respectively. The determination of intra- and inter-day precision (RSD) was less than 2.5 and 3.5%, at all concentration levels, while the inter- and intra-day accuracy (% difference) was less than 4.9-6.2%. This method is being used in a therapeutic drug monitoring service to quantitate these therapeutic agents in patients for pharmacokinetic studies.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12504198     DOI: 10.1016/s1570-0232(02)00759-6

Source DB:  PubMed          Journal:  J Chromatogr B Analyt Technol Biomed Life Sci        ISSN: 1570-0232            Impact factor:   3.205


  6 in total

1.  Novel and validated titrimetric method for determination of selected angiotensin-II-receptor antagonists in pharmaceutical preparations and its comparison with UV spectrophotometric determination.

Authors:  Shrikant H Patil; Minakshi V Janjale
Journal:  J Pharm Anal       Date:  2012-04-09

2.  Ion Pair-HPLC Method for the Simultaneous Estimation of Quinapril and Hydrochlorothiazide in Tablets.

Authors:  M Gandhimathi; T K Ravi
Journal:  Indian J Pharm Sci       Date:  2009-05       Impact factor: 0.975

3.  A validated stability indicating HPTLC method for simultaneous estimation of irbesartan and hydrochlorothiazide.

Authors:  Amol S Khodke; Laxman V Potale; Mrinalini C Damle; Kailash G Bothara
Journal:  Pharm Methods       Date:  2010-10

4.  A validated stability-indicating liquid chromatographic method for determination of process related impurities and degradation behavior of Irbesartan in solid oral dosage.

Authors:  Nishant Goswami
Journal:  J Adv Pharm Technol Res       Date:  2014-01

5.  Quantitative Determination of three Angiotensin-II-receptor Antagonists in Presence of Hydrochlorothiazide by RP-HPLC in their Tablet Preparations.

Authors:  Hany Mohammed Hafez; Abdullah Ahmed Elshanawane; Lobna Mohammed Abdelaziz; Magda Mohammed Kamal
Journal:  Iran J Pharm Res       Date:  2013       Impact factor: 1.696

6.  New ultra-performance liquid chromatography-tandem mass spectrometry method for the determination of irbesartan in human plasma.

Authors:  Tanveer A Wani; Seema Zargar
Journal:  J Food Drug Anal       Date:  2015-03-26       Impact factor: 6.157

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.