Literature DB >> 12504056

Beam orientation selection for intensity-modulated radiation therapy based on target equivalent uniform dose maximization.

Shiva Das1, Timothy Cullip, Gregg Tracton, Sha Chang, Lawrence Marks, Mitchell Anscher, Julian Rosenman.   

Abstract

PURPOSE: To develop an automated beam-orientation selection procedure for intensity-modulated radiotherapy (IMRT), and to determine if a small number of beams picked by this automated procedure can yield results comparable to a large number of manually placed orientations. METHODS AND MATERIALS: The automated beam selection procedure maximizes an unconstrained objective function composed of target equivalent uniform dose (EUD) and critical structure dose-volume histogram (DVH) constraints. Beam orientations are selected from a large feasible set of directions through a series of alternating fluence optimization and orientation alteration steps, until convergence to a stable orientation set. The fluence optimization step adjusts fluences to maximize the objective function. The orientation alteration step substitutes beams in the orientation set currently under consideration with beams of the parent set in the immediate angular vicinity; the altered orientation set is deemed current if it produces a higher objective function value in the fluence optimization step. RESULTS AND
CONCLUSIONS: It is demonstrated, for prostate IMRT planning, that a modest number of appropriately selected beam orientations (3 or 5) can provide dose distributions as satisfactory as those produced by a large number of unselected equispaced orientations. Such selected beam orientations can reduce overall treatment time, thus making IMRT more clinically practical.

Mesh:

Year:  2003        PMID: 12504056     DOI: 10.1016/s0360-3016(02)03817-8

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  6 in total

1.  Assessment and quantification of patient set-up errors in nasopharyngeal cancer patients and their biological and dosimetric impact in terms of generalized equivalent uniform dose (gEUD), tumour control probability (TCP) and normal tissue complication probability (NTCP).

Authors:  A Boughalia; S Marcie; M Fellah; S Chami; F Mekki
Journal:  Br J Radiol       Date:  2015-04-17       Impact factor: 3.039

2.  Standardized beam bouquets for lung IMRT planning.

Authors:  Lulin Yuan; Q Jackie Wu; Fangfang Yin; Ying Li; Yang Sheng; Christopher R Kelsey; Yaorong Ge
Journal:  Phys Med Biol       Date:  2015-02-06       Impact factor: 3.609

3.  A surrogate-based metaheuristic global search method for beam angle selection in radiation treatment planning.

Authors:  H H Zhang; S Gao; W Chen; L Shi; W D D'Souza; R R Meyer
Journal:  Phys Med Biol       Date:  2013-03-21       Impact factor: 3.609

4.  A hybrid IMRT/VMAT technique for the treatment of nasopharyngeal cancer.

Authors:  Nan Zhao; Ruijie Yang; Yuliang Jiang; Suqing Tian; Fuxin Guo; Junjie Wang
Journal:  Biomed Res Int       Date:  2015-01-21       Impact factor: 3.411

5.  Planning quality and delivery efficiency of sMLC delivered IMRT treatment of oropharyngeal cancers evaluated by RTOG H-0022 dosimetric criteria.

Authors:  X Ronald Zhu; Christopher J Schultz; Michael T Gillin
Journal:  J Appl Clin Med Phys       Date:  2004-10-01       Impact factor: 2.102

6.  The Scatter Search Based Algorithm for Beam Angle Optimization in Intensity-Modulated Radiation Therapy.

Authors:  Ali Ghanbarzadeh; Majid Pouladian; Ali Shabestani Monfared; Seied Rabi Mahdavi
Journal:  Comput Math Methods Med       Date:  2018-06-03       Impact factor: 2.238

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.