Literature DB >> 12502053

The quality of drinking water from private water supplies in Aberdeenshire, UK.

Donald C Reid1, Anthony C Edwards, David Cooper, Elaine Wilson, Brian A Mcgaw.   

Abstract

The quality of private water supplies within Aberdeenshire sampled between 1992 and 1998 was analysed with respect to the presence of total coliforms (TC), faecal coliforms (FC), and nitrate. Of the approximately 1750 samples analysed, which included multiple samples from larger supply categories, the individual failure rate was 41%, 30% and 15% for TC, FC and nitrate, respectively. A combined failure rate for these samples was 48%. Failure rates on microbiological grounds displayed a seasonal trend being greater during the latter half of the year. Although this observation is likely to be due to a combination of local and regional scale factors, part of the variability in failure rate was explained by a significant positive relationship with rainfall amount. Concentrations of nitrate tended to display an opposite trend with a greater number of failures occurring during the spring period and no relationship with rainfall was immediately apparent. A relatively small number of samples (< 50) failed simultaneously for both coliforms and nitrate suggesting that the mechanism responsible for the contamination differed. A similar failure rate for samples collected directly from the source (i.e. well) compared with those taken from the potable tap (usually kitchen cold water tap) suggests that it is the groundwater source itself that contributes much of the microbiological and nitrate contamination rather than a storage or supply line contamination mechanism. A more frequent and random sampling of category one F supplies suggested a greater overall failure rate, which has its own implications for deciding an appropriate sampling frequency.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12502053     DOI: 10.1016/s0043-1354(02)00266-x

Source DB:  PubMed          Journal:  Water Res        ISSN: 0043-1354            Impact factor:   11.236


  6 in total

1.  Optimization of nitrate reduction by EDTA catalyzed zero-valent bimetallic nanoparticles in aqueous medium.

Authors:  Kunwar P Singh; Arun K Singh; Shikha Gupta
Journal:  Environ Sci Pollut Res Int       Date:  2012-06-08       Impact factor: 4.223

2.  Impact of long-term wastewater application on microbiological properties of vadose zone.

Authors:  Santosh K Deshmukh; Anil Kumar Singh; Siba Prasad Datta; K Annapurna
Journal:  Environ Monit Assess       Date:  2010-06-18       Impact factor: 2.513

3.  Distribution of nitrogen species in groundwater aquifers of an industrial area in alluvial Indo-Gangetic Plains--a case study.

Authors:  Kunwar P Singh; Vinod K Singh; Amrita Malik; Nikita Basant
Journal:  Environ Geochem Health       Date:  2006-06-22       Impact factor: 4.609

4.  Contaminated small drinking water supplies and risk of infectious intestinal disease: a prospective cohort study.

Authors:  Helen L Risebro; Lynette Breton; Heather Aird; Alan Hooper; Paul R Hunter
Journal:  PLoS One       Date:  2012-08-24       Impact factor: 3.240

5.  Determination of aluminium and physicochemical parameters in the palm oil estates water supply at Johor, Malaysia.

Authors:  M R Siti Farizwana; S Mazrura; A Zurahanim Fasha; G Ahmad Rohi
Journal:  J Environ Public Health       Date:  2011-03-07

6.  Variability in the chemistry of private drinking water supplies and the impact of domestic treatment systems on water quality.

Authors:  E L Ander; M J Watts; P L Smedley; E M Hamilton; R Close; H Crabbe; T Fletcher; A Rimell; M Studden; G Leonardi
Journal:  Environ Geochem Health       Date:  2016-01-25       Impact factor: 4.609

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.