Literature DB >> 12502044

A standard dosimetry procedure for 192Ir sources used for endovascular brachytherapy.

A Piermattei1, A Fidanzio, L Azario, A Russo, F Perrone, R Capote, M P Toni.   

Abstract

The experimental dosimetry of a high dose rate (HDR) 192Ir source used for the brachytherapy of peripheral vessels is reported. The direct determination of the reference air kerma rate Kr agrees, within the experimental uncertainty, with the results obtained by a well ionization chamber calibrated at the NIST and the manufacturer's certification. A highly sensitive (HS) radiochromic film (RCF), that presents only one active layer, was used for the source dosimetry in a water phantom. The adopted experimental set-up, with the source in its catheter positioned on the RCF plane, seems to have given better accuracy of the RCF optical density measurements. The agreement between the measurement of the dose rate constant DKr (10 mm, pi/2) and the literature data confirmed the coherence of the HS RCF calibration obtained by the kerma in air measurements. The RCF measurements supplied dosimetric information about the dose to water per reference air kerma rate D(r, theta)/Kr along the source transverse bisector axis, the radial dose function g(r) and the anisotropy function F(r, theta). The value D(2 mm, pi/2)/Kr = 22.4 +/- 1.2 cGy h(-1)/(microGy h(-1)) is supplied with a dose uncertainty that is essentially due to the indeterminacy of the source position in the catheter. The data of the radial and anisotropy functions have been compared with Monte Carlo determinations reported in the literature.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12502044     DOI: 10.1088/0031-9155/47/23/307

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  2 in total

1.  Spatial dose distributions in solid tumors from 186Re transported by liposomes using HS radiochromic media.

Authors:  Luis A Medina; Beth Goins; Mercedes Rodríguez-Villafuerte; Ande Bao; Arnulfo Martínez-Davalos; Vibhudutta Awasthi; Olga O Galván; Cristina Santoyo; William T Phillips; María-Ester Brandan
Journal:  Eur J Nucl Med Mol Imaging       Date:  2007-02-08       Impact factor: 10.057

2.  Gafchromic film dosimetry of a new HDR 192Ir brachytherapy source.

Authors:  Navid Ayoobian; Akbar Sarabi Asl; Hosein Poorbaygi; Mohammad Reza Javanshir
Journal:  J Appl Clin Med Phys       Date:  2016-03-08       Impact factor: 2.102

  2 in total