Literature DB >> 12498854

Pupil diameter changes and reaction after posterior chamber phakic intraocular lens implantation.

Richard J Keuch1, Heinrich Bleckmann.   

Abstract

PURPOSE: To compare the different aspects of pupil constriction before and after the implantation of an implantable contact lens (ICL).
SETTING: Augenabteilung der Schlosspark-Klinik Berlin, Berlin, Germany.
METHODS: This study comprised 15 myopic and 9 hyperopic eyes that were evaluated before and after the implantation of an ICL using a compact integrated pupillograph (CIP, AMTech) under standardized conditions. The preoperative and postoperative pupil diameters, rate and latency of the pupil reaction, and amplitude of constriction were compared.
RESULTS: The latency and the duration of pupil constriction were significantly prolonged after ICL implantation. The rate of pupil contraction and redilation, the pupil diameter, and the amplitude of pupil constriction were reduced after ICL implantation.
CONCLUSIONS: The pupil reaction after implantation of a phakic posterior chamber ICL was slower. The postoperative pupil diameter was smaller, and the amplitude of constriction was reduced. The changes have not proved to be clinically significant to date.

Entities:  

Mesh:

Year:  2002        PMID: 12498854     DOI: 10.1016/s0886-3350(02)01355-x

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  5 in total

Review 1.  [Phakic intraocular lenses. Current status and limitations].

Authors:  H B Dick; M Tehrani
Journal:  Ophthalmologe       Date:  2004-03       Impact factor: 1.059

2.  Clear-cornea cataract surgery: pupil size and shape changes, along with anterior chamber volume and depth changes. A Scheimpflug imaging study.

Authors:  Anastasios John Kanellopoulos; George Asimellis
Journal:  Clin Ophthalmol       Date:  2014-10-24

3.  Evaluation of Disk Halo Size after Implantation of a Collamer Lens with a Central Hole (ICL V4c).

Authors:  Xun Chen; Tian Han; Feng Zhao; Huamao Miao; Xiaoying Wang; Xingtao Zhou
Journal:  J Ophthalmol       Date:  2019-08-14       Impact factor: 1.909

4.  Pupil Diameter Changes in High Myopes after Collamer Lens Implantation.

Authors:  Dan Li; Yabo Yang; Caipei Su; Houfa Yin; Xue Liu
Journal:  Optom Vis Sci       Date:  2015-12       Impact factor: 1.973

5.  Pupil dynamics after in-the-bag versus anterior and retropupillary iris-fixated intraocular lens implantation.

Authors:  Yanxiu Sun; Maximilian Hammer; Timur M Yildirim; Ramin Khoramnia; Gerd U Auffarth
Journal:  Sci Rep       Date:  2021-11-02       Impact factor: 4.379

  5 in total