Literature DB >> 12498576

Quantification of mass fluxes and natural attenuation rates at an industrial site with a limited monitoring network: a case study.

Alexander Bockelmann1, Daniela Zamfirescu, Thomas Ptak, Peter Grathwohl, Georg Teutsch.   

Abstract

At many "real world" field sites, the number of available monitoring wells is limited due to economic or geological reasons. Under such restricted conditions, it is difficult to perform a reliable field investigation and to quantify primary lines of evidence for natural attenuation (NA), like the documentation of a decrease of contaminant mass flux in flow direction. This study reports the results of a groundwater investigation at a former manufactured gas plant situated in a Quaternary river valley in southwest Germany. The location, infrastructure and aquifer setting are typical of many industrial sites in Germany. Due to difficult drilling conditions (coarse glaciofluvial gravel deposits and an anthropogenic fill above the aquifer), only 12 monitoring wells were available for the investigation and localisation of the contaminant plume. These wells were situated along three control planes (CP) downgradient from the contaminant source, with four wells along each plane. Based on the sparse set of monitoring wells, field scale mass fluxes and first-order natural attenuation rate constants of benzene, toluene, ethylbenzene, and o-xylene and p-xylene (BTEX) and low molecular weight polycyclic aromatic hydrocarbons (PAH) were estimated utilizing different point scale and also a new integral investigation method. The results show that even at a heterogeneous site with a sparse monitoring network point scale investigation methods can provide reliable information on field scale natural attenuation rates, if a dependable flow model or tracer test data is available. If this information is not available, only the new integral investigation method presented can yield adequate results for the quantification of contaminant mass fluxes under sparse monitoring conditions.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12498576     DOI: 10.1016/s0169-7722(02)00060-8

Source DB:  PubMed          Journal:  J Contam Hydrol        ISSN: 0169-7722            Impact factor:   3.188


  4 in total

1.  Characterization and Remediation of Chlorinated Volatile Organic Contaminants in the Vadose Zone: An Overview of Issues and Approaches.

Authors:  Mark L Brusseau; Kenneth C Carroll; Michael J Truex; David J Becker
Journal:  Vadose Zone J       Date:  2013-11-01       Impact factor: 3.289

2.  Management of large dilute plumes of chloroethenes and 1,4-dioxane via monitored natural attenuation (MNA) and MNA augmentation.

Authors:  Lee K Rhea; Catherine Clark
Journal:  Remediation (N Y)       Date:  2022-02-07

3.  Characterizing long-term contaminant mass discharge and the relationship between reductions in discharge and reductions in mass for DNAPL source areas.

Authors:  M L Brusseau; D E Matthieu; K C Carroll; J Mainhagu; C Morrison; A McMillan; A Russo; M Plaschke
Journal:  J Contam Hydrol       Date:  2013-03-05       Impact factor: 3.188

4.  Measuring spatial variability of vapor flux to characterize vadose-zone VOC sources: flow-cell experiments.

Authors:  J Mainhagu; C Morrison; M Truex; M Oostrom; M L Brusseau
Journal:  J Contam Hydrol       Date:  2014-08-05       Impact factor: 3.188

  4 in total