Literature DB >> 12498468

Immediate loading implants: a clinical report of 1301 implants.

Arturo Hruska1, Paolo Borelli, Assia Chiaramonte Bordanaro, Eleonora Marzaduri, Kurt-Lorenzo Hruska.   

Abstract

The purpose of this study is to suggest 4 immediate load of implants techniques that are alternative and/or complementary to the traditional submersion technique. These techniques meet the criteria for implant immobilization during the entire period of osteointegration, and are based on the principles of splinting and load sharing. One hundred fifty-three maxillary and 309 mandibular arches were treated with 1301 implants. Only implants that satisfied the primary retention were immediately loaded with a provisional crown with wings (94), provisional plastic prosthesis (478), provisional plastic prosthesis with metal frame (293), and intraoral welding (436). Facies morphology, type of occlusion, size and function of the tongue, bone density, number, and length of implants appeared to have an influence on the results. Success rates achieved over 21 years are 99.3% with the intraoral welding machine, 98.3% with the provisional plastic prosthesis with metal frame, 97.9% with metal wings, and 88.02% with provisional plastic prosthesis. This last percentage is reflective of the years 1974 to 1984 when only blade-forms and root-forms with unscrewable abutments were available and a provisional plastic prosthesis was the only immobilization technique known. Guidelines are proposed for a treatment plan indicating when and why immediate loading implants can be suggested.

Mesh:

Substances:

Year:  2002        PMID: 12498468     DOI: 10.1563/1548-1336(2002)028<0200:ILIACR>2.3.CO;2

Source DB:  PubMed          Journal:  J Oral Implantol        ISSN: 0160-6972            Impact factor:   1.779


  3 in total

1.  Comparative evaluation of soft and hard tissue changes following endosseous implant placement using flap and flapless techniques in the posterior edentulous areas of the mandible-a randomized controlled trial.

Authors:  Divya Kumar; G Sivaram; B Shivakumar; Tss Kumar
Journal:  Oral Maxillofac Surg       Date:  2018-05-05

2.  Long-term follow-up of dental single implants under immediate orthodontic load.

Authors:  Lisiane Meira Palagi; Carlos Eduardo Sabrosa; Eveline C B Gava; Tiziano Baccetti; Jose Augusto M Miguel
Journal:  Angle Orthod       Date:  2010-09       Impact factor: 2.079

3.  The Ball Welding Bar: A New Solution for the Immediate Loading of Screw-Retained, Mandibular Fixed Full Arch Prostheses.

Authors:  Danilo Bacchiocchi; Andrea Guida
Journal:  Int J Dent       Date:  2017-08-01
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.