Literature DB >> 12493169

Use of simulated blood cultures for time to detection comparison between BacT/ALERT and BACTEC 9240 blood culture systems.

Egidio Francesco Viganò1, Emanuela Vasconi, Carlo Agrappi, Pierangelo Clerici.   

Abstract

In order to avoid the influence of pre-analytical steps, the following study was performed by using sterile blood spiked with defined loads of microorganisms as inoculum. Time-to-Detection (TTD) was evaluated for the most frequently encountered bacteria and fungi in septicemia, comparing two commercially available blood culture systems, BACTEC 9240 (Becton Dickinson) and BacT/ALERT (Organon Teknika). A specific medium, Bactec Mycosis IC/F (Becton Dickinson), was compared with the Bactec Plus Aerobic (Becton Dickinson) and FAN Aerobic (Organon Teknika) media for recovery of fungi in general and in case of mixed bacterial/fungal septicemia. The results show that the BACTEC system detects nearly all enrolled microorganisms significantly faster than the BacT/ALERT; the anaerobic vial contributes to the detection of anaerobes and facultative anaerobes and, in the case of BACTEC, shortens TTD; the Bactec Mycosis IC/F bottle shortens TTD of fungi.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12493169     DOI: 10.1016/s0732-8893(02)00451-0

Source DB:  PubMed          Journal:  Diagn Microbiol Infect Dis        ISSN: 0732-8893            Impact factor:   2.803


  16 in total

1.  Effect of inoculum size on detection of Candida growth by the BACTEC 9240 automated blood culture system using aerobic and anaerobic media.

Authors:  Benjamin J George; Lynn L Horvath; Duane R Hospenthal
Journal:  J Clin Microbiol       Date:  2005-01       Impact factor: 5.948

2.  Over 18 h to positivity in the BacT/ALERT system with clustered Gram-positive cocci is highly predictive of coagulase-negative staphylococci.

Authors:  Ricardo A Zimerman; Denise P Machado; Caroline C Constante; Afonso L Barth; Luciano Z Goldani
Journal:  J Clin Pathol       Date:  2007-02-13       Impact factor: 3.411

3.  Using the polymerase chain reaction coupled with denaturing gradient gel electrophoresis to investigate the association between bacterial translocation and systemic inflammatory response syndrome in predicted acute severe pancreatitis.

Authors:  Callum B Pearce; Vitaly Zinkevich; Iwona Beech; Viera Funjika; Ana Garcia Ruiz; Afraa Aladawi; Hamish D Duncan
Journal:  World J Gastroenterol       Date:  2005-12-07       Impact factor: 5.742

4.  Comparison of BD Bactec Plus blood culture media to VersaTREK Redox blood culture media for detection of bacterial pathogens in simulated adult blood cultures containing therapeutic concentrations of antibiotics.

Authors:  Nancy S Miller; Dagmar Rogan; Beverley L Orr; Dana Whitney
Journal:  J Clin Microbiol       Date:  2011-02-09       Impact factor: 5.948

5.  Comparison of BD Bactec Plus Aerobic/F medium to VersaTREK Redox 1 blood culture medium for detection of Candida spp. in seeded blood culture specimens containing therapeutic levels of antifungal agents.

Authors:  Stefan Riedel; Stephen W Eisinger; Lisa Dam; Paul D Stamper; Karen C Carroll
Journal:  J Clin Microbiol       Date:  2011-01-26       Impact factor: 5.948

6.  Efficiency of blood culture bottles for the fungal sterility testing of corneal organ culture media.

Authors:  G Thuret; A Carricajo; A C Vautrin; H Raberin; S Acquart; O Garraud; P Gain; G Aubert
Journal:  Br J Ophthalmol       Date:  2005-05       Impact factor: 4.638

7.  Comparison of Mycosis IC/F and plus Aerobic/F media for diagnosis of fungemia by the bactec 9240 system.

Authors:  Marie-Hélène Meyer; Valérie Letscher-Bru; Benoît Jaulhac; Jocelyn Waller; Ermanno Candolfi
Journal:  J Clin Microbiol       Date:  2004-02       Impact factor: 5.948

8.  Direct comparison of the BACTEC 9240 and BacT/ALERT 3D automated blood culture systems for candida growth detection.

Authors:  Lynn L Horvath; Benjamin J George; Clinton K Murray; Linda S Harrison; Duane R Hospenthal
Journal:  J Clin Microbiol       Date:  2004-01       Impact factor: 5.948

Review 9.  The era of molecular and other non-culture-based methods in diagnosis of sepsis.

Authors:  Nicasio Mancini; Silvia Carletti; Nadia Ghidoli; Paola Cichero; Roberto Burioni; Massimo Clementi
Journal:  Clin Microbiol Rev       Date:  2010-01       Impact factor: 26.132

10.  Detection of fifteen species of Candida in an automated blood culture system.

Authors:  Lynn L Horvath; Benjamin J George; Duane R Hospenthal
Journal:  J Clin Microbiol       Date:  2007-07-11       Impact factor: 5.948