Literature DB >> 1249047

Gas-liquid chromatographic determination of nikethamide in injectable preparations.

J M Newton.   

Abstract

A gas-liquid chromatographic (GLC) method, using a 4% XE-60 on 80-100 mesh Gas-Chrom Q column, a flame ionization detector, and anthracene as the internal standard, has been developed for the direct determination of nikethamide. Eight collaborators analyzed 4 samples, using methanol as the solvent; the coefficients of variation obtained ranged from 1.19 to 3.20%. In a limited study with acetone as the solvent, the coefficients of variation ranged from 0.59 to 1.96%. The GLC method with acetone as a solvent has been adopted as official first action.

Entities:  

Mesh:

Substances:

Year:  1976        PMID: 1249047

Source DB:  PubMed          Journal:  J Assoc Off Anal Chem        ISSN: 0004-5756


  1 in total

1.  Excretion and metabolism of nikethamide in the horse.

Authors:  F T Delbeke; M Debackere
Journal:  Br J Sports Med       Date:  1976-10       Impact factor: 13.800