Literature DB >> 12487777

Influence of heparin coating of coronary stents and ex vivo efficacy of different doses of acetylsalicylic acid and ticlopidine in a pulsed floating model of recirculating human plasma.

Marc A Brockmann1, Kai Gutensohn, Juliane Bau, Peter Kuehnl, Thomas Meinertz, Christian Nienaber, Christian Beythien.   

Abstract

Acute occlusion of stented coronary vessels still occurs in up to 3%. Activated platelets have been found to play a major role in the pathogenesis of these complications. We therefore analyzed the efficacy of a heparin coating of coronary stents and investigated the ex vivo efficacy of different antiplatelet drugs. Each of seven healthy volunteers was treated with each of the following medications for 7 days: ASA 100 mg/day, ASA 300 mg/day, ticlopidine 250 mg/day, and ticlopidine 500 mg/day. Three standardized in vitro silicon tubing models, one of them containing an uncoated stent, one a heparin-coated stent, and one without a stent (control) were filled with PRP and circulation was started. TOS in systems with heparin-coated stents was 2.4-times longer compared to systems with uncoated stents (P<0.001), and 1.5-times longer compared to the control (P<0.01). The increase of CD62p expression within the first 5 min was 2.5-times higher in systems with uncoated stents and 1.7-times higher in the control than in systems with heparin-coated stents (P<0.05). Aggregometry revealed significant medication- and dose-dependent inhibition of platelet aggregability for all medications. Heparin-coating of coronary stents reduces their thrombogenicity significantly. ASA and ticlopidine effectively reduce platelet activation ex vivo. The used in vitro system facilitates a reproducible method to estimate the thrombogenicity of coronary stents prior to in vivo trials.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12487777     DOI: 10.1080/0953710021000057802

Source DB:  PubMed          Journal:  Platelets        ISSN: 0953-7104            Impact factor:   3.862


  3 in total

1.  Comparison of high-resolution X-ray and micro-CT for experimental evaluation of intracranial stent prototypes: quality evaluation beyond CE mark.

Authors:  Andreas Keuler; Christian Taschner; Marc Alexander Brockmann; Hanne Boll; Katharina Förster; Lisa Lutz; Annegret Herrmann-Frank; Monika Lelgemann; Martin Schumacher
Journal:  Neuroradiology       Date:  2014-01-31       Impact factor: 2.804

2.  Characterization of Endothelial Progenitor Cell Interactions with Human Tropoelastin.

Authors:  Young Yu; Steven G Wise; Praveesuda L Michael; Daniel V Bax; Gloria S C Yuen; Matti A Hiob; Giselle C Yeo; Elysse C Filipe; Louise L Dunn; Kim H Chan; Hamid Hajian; David S Celermajer; Anthony S Weiss; Martin K C Ng
Journal:  PLoS One       Date:  2015-06-26       Impact factor: 3.240

3.  Platelet function testing in pigs using the Multiplate® Analyzer.

Authors:  Sarah Heringer; Lisa Kabelitz; Martin Kramer; Omid Nikoubashman; Marc A Brockmann; Stefanie Kirschner; Martin Wiesmann
Journal:  PLoS One       Date:  2019-08-29       Impact factor: 3.240

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.