Literature DB >> 12486511

The effect of sample treatment on separation profiles of tear fluid proteins: qualitative and semi-quantitative protein determination by an automated analysis system.

Otto Schmut1, Jutta Horwath-Winter, Andrea Zenker, Gabriele Trummer.   

Abstract

PURPOSE: Qualitative and quantitative determination of tear fluid components is of increasing interest in ophthalmology. Until now, for diagnosis and course control of some diseases of the anterior parts of the eye, different methods for tear fluid protein analysis are available. Results can be obtained by polyacrylamide gel electrophoresis (PAGE), immunochemistry, and high-performance liquid chromatography (HPLC). A new method for protein separation, identification and semi-quantitative determination on a chip-based micro-fluidic technique is used for the first time to investigate tear fluids.
METHODS: Normal human reflex tears were obtained by stimulation with China mint oil and collected using glass capillary tubes. A lab-on-a-chip technology (developed by Agilent Technologies, Waldbronn, Germany, in co-operation with Caliper Technologies, Mountain View, California, USA) was used for separation and semi-quantitative determination of tear proteins. Tear fluid was separated on the Agilent 2100 Bioanalyzer in combination with the Protein 200 LabChip kit and the dedicated protein assay software. Time and temperature of the incubation with sample buffer were varied, and the influence of these parameters on protein separation profiles was studied. Tear proteins were also analysed by PAGE, and the results obtained by both methods were compared.
RESULTS: The different proteins of tear fluid can be separated by the Agilent 2100 Bioanalyzer method in very short time. By this method, the molecular weight as well as the concentration of proteins can be determined. Data are automatically stored in digital format and can be retrieved and shared. Results of this technology were comparable with the protein pattern obtained by PAGE. It was confirmed by both methods that, depending on incubation time of tear fluid with sample buffer and on temperature, different protein pattern can be obtained from the tears of one specimen.
CONCLUSION: Tear proteins - in contrast to serum or aqueous humour proteins - are very sensitive to changes in sample buffer temperature as well as incubation time with buffer. To obtain comparable results for tear fluid proteins, the sample buffer applied and the incubation time and temperature must be observed carefully. This can be demonstrated by both the new Agilent 2100 Bioanalyzer method and PAGE. These results are of importance when comparing tear fluid protein pattern for the diagnosis and course control of dry-eye syndrome and of other diseases of the anterior part of the eye.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12486511     DOI: 10.1007/s00417-002-0537-0

Source DB:  PubMed          Journal:  Graefes Arch Clin Exp Ophthalmol        ISSN: 0721-832X            Impact factor:   3.117


  7 in total

1.  Effect of contact lenses on the protein composition in tear film: a ProteinChip study.

Authors:  Christina Kramann; Nils Boehm; Katrin Lorenz; Nelli Wehrwein; Bernhard M Stoffelns; Norbert Pfeiffer; Franz H Grus
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2010-07-26       Impact factor: 3.117

2.  Single eye analysis and contralateral eye comparison of tear proteins in normal and dry eye model rabbits by MALDI-ToF mass spectrometry using wax-coated target plates.

Authors:  Bryan M Ham; Jean T Jacob; Richard B Cole
Journal:  Anal Bioanal Chem       Date:  2007-01-09       Impact factor: 4.142

3.  Comparative studies on the analysis of glycoproteins and lipopolysaccharides by the gel-based microchip and SDS-PAGE.

Authors:  Jung-Feng Hsieh; Shui-Tein Chen
Journal:  Biomicrofluidics       Date:  2007-01-01       Impact factor: 2.800

Review 4.  Proteomic and Transcriptomic Techniques to Decipher the Molecular Evolution of Venoms.

Authors:  Stephanie Mouchbahani-Constance; Reza Sharif-Naeini
Journal:  Toxins (Basel)       Date:  2021-02-16       Impact factor: 4.546

Review 5.  A Review of Emerging Tear Proteomics Research on the Ocular Surface in Ocular Allergy.

Authors:  Esrin Aydin; Poshmaal Dhar; Moneisha Gokhale; Luke Chong; Serap Azizoglu; Cenk Suphioglu
Journal:  Biology (Basel)       Date:  2022-02-16

6.  A rapid standardized quantitative microfluidic system approach for evaluating human tear proteins.

Authors:  Piera Versura; Alberto Bavelloni; William Blalock; Michela Fresina; Emilio C Campos
Journal:  Mol Vis       Date:  2012-10-12       Impact factor: 2.367

Review 7.  Practical issues concerning tear protein assays in dry eye.

Authors:  Sharon D'Souza; Louis Tong
Journal:  Eye Vis (Lond)       Date:  2014-11-13
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.