Literature DB >> 12483354

Postshunt insertion CSF leaks in infants treated by an adjustable valve opening pressure reduction.

Veit Rohde1, Martin Weinzierl, Lothar Mayfrank, Joachim M Gilsbach.   

Abstract

OBJECTS: Cerebrospinal fluid (CSF) leakages through the operation wound following shunt placement are commonly treated by head elevation when the shunt is patent and signs of infection are absent. METHODS AND
RESULTS: In two cases in which the standard therapy of head elevation failed, the leakage was successfully managed by temporary lowering of the opening pressure of the implanted programmable valve. Case 1 was that of a preterm baby with repaired meningomyelocele and shunted hydrocephalus. A shunt infection made shunt removal necessary. Five days after insertion of a new ventriculoperitoneal shunt, transcutaneous CSF flow occurred. The CSF leak was cured by a temporary reduction of the opening pressure from 70 to 30 mm H(2)0. Case 2 was in a 9-month-old child with shunted posthaemorrhagic hydrocephalus. Shunt infection was treated by shunt removal, placement of external ventricular drainage, and antibiotics. CSF leakage through the operation wound developed 24 h after placement of the new ventriculoperitoneal shunt. The CSF leakage was successfully treated by temporarily lowering the opening pressure of the valve from 100 to 50 mm H(2)0.
CONCLUSION: The authors assume that head elevation alone did not generate a sufficient difference between the ventricular and the abdominal pressure for the selected opening pressure of the valve to be exceeded, with the result that CSF flowed around the ventricular catheter and through the operation wound. It is believed that reduction of the opening pressure of the valve led to CSF flow through the shunt and made siphoning possible, resulting in cessation of the transcutaneous CSF flow. The authors propose the prophylactic implantation of a programmable valve in children at high risk of postoperative transcutaneous CSF leakage.

Entities:  

Mesh:

Year:  2002        PMID: 12483354     DOI: 10.1007/s00381-002-0620-1

Source DB:  PubMed          Journal:  Childs Nerv Syst        ISSN: 0256-7040            Impact factor:   1.475


  3 in total

1.  The Strata programmable valve for shunt-dependent hydrocephalus: the pediatric experience at a single institution.

Authors:  Edward S Ahn; Markus Bookland; Benjamin S Carson; Jon D Weingart; George I Jallo
Journal:  Childs Nerv Syst       Date:  2006-10-07       Impact factor: 1.475

Review 2.  Shunts vs endoscopic third ventriculostomy in infants: are there different types and/or rates of complications? A review.

Authors:  C Di Rocco; L Massimi; G Tamburrini
Journal:  Childs Nerv Syst       Date:  2006-10-20       Impact factor: 1.475

3.  Management of neonatal hydrocephalus: feasibility of use and safety of two programmable (Sophy and Polaris) valves.

Authors:  Juan F Martínez-Lage; María-José Almagro; Isabel Sanchez Del Rincón; Miguel A Pérez-Espejo; Claudio Piqueras; Raúl Alfaro; Javier Ros de San Pedro
Journal:  Childs Nerv Syst       Date:  2007-10-09       Impact factor: 1.475

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.