Reliability of the response AC/A ratio determined using nearpoint autorefraction and simultaneous heterophoria measurement.

Bill B Rainey1, David A Goss, Melinda Kidwell, Brian Feng.   

Abstract

BACKGROUND: Clinicians frequently assess the accommodative convergence to accommodation (AC/A) ratio using near phoria measurements and accommodative stimuli. The purpose of this study was to evaluate the repeatability of AC/A ratio measurements and to compare the response AC/A ratio to stimulus AC/A ratios determined two different ways.
METHODS: Heterophorias and accommodative responses to different stimuli were measured simultaneously on eight subjects at two visits. A Canon Auto Ref R-1 autorefractor was used to measure accommodative response, while vergence posture was measured using the modified Thorington heterophoria technique. These results were used to calculate response-slope, stimulus-slope and stimulus-gradient AC/A ratios and the means of these ratios for each session were compared. Correlations between the response AC/A ratios and the stimulus AC/A ratios were calculated.
RESULTS: The mean response AC/A ratios for the two sessions were 3.8 prism dioptres per dioptre for each session. The correlation between the slope-determined ratios was 0.56, and between the response-slope and the stimulus-gradient AC/A ratios the correlation was -0.03. The regression equation for the slope-determined AC/A ratios was calculated.
CONCLUSIONS: Means for the two sessions were not significantly different for any of the AC/A ratios. The response-slope and stimulus-slope AC/A ratios had a moderately significant correlation and a predictive regression equation was determined. The stimulus-gradient AC/A ratios were not correlated with the response-slope AC/A ratios.

Year:  1998        PMID: 12482317     DOI: 10.1111/j.1444-0938.1998.tb06733.x

Source DB:  PubMed          Journal:  Clin Exp Optom        ISSN: 0816-4622            Impact factor:   2.742


  3 in total

1.  The clinical near gradient stimulus AC/A ratio correlates better with the response CA/C ratio than with the response AC/A ratio.

Authors:  Anna M Horwood; Patricia M Riddell
Journal:  Strabismus       Date:  2013-06

2.  Changes in stimulus and response AC/A ratio with vision therapy in Convergence Insufficiency.

Authors:  Neeraj Kumar Singh; Revathy Mani; Jameel Rizwana Hussaindeen
Journal:  J Optom       Date:  2017-01-24

Review 3.  Convergence insufficiency: Review of clinical diagnostic signs.

Authors:  Liat Gantz; Hadas Stiebel-Kalish
Journal:  J Optom       Date:  2021-12-25
  3 in total