Abstract

Ring-shaped lead zirconate titanate (PZT) piezoelectric vibrators were subjected to non-uniform mechanical stress applied by bolt clamping. The effect of mechanical stress on the effective electromechanical coupling factor (k(eff)) and mechanical quality factor (Qm) of the thickness and wall thickness modes was studied by an equivalent electric circuit analysis. The initiation and propagation of cracks under mechanical stress were also discussed based on the resonance method and the indentation technique. k(eff) for both the thickness and wall thickness modes decreased with increase in mechanical stress due to de-poling of the PZT. Qm of the thickness mode dropped sharply with increase in mechanical stress while Qm of the wall thickness mode remained almost unchange. Existence of microcracks in a PZT vibrator can be detected by the occurrence of spurious vibrations at the wall thickness mode in the electrical impedance vs. frequency spectra.

Year:  2002        PMID: 12479605     DOI: 10.1016/s0041-624x(02)00378-5