Literature DB >> 12477219

Lung deposition of salbutamol in healthy human subjects from the MAGhaler dry powder inhaler.

S Newman1, S Malik, R Hirst, G Pitcairn, A Heide, J Pabst, A Dinkelaker, W Fleischer.   

Abstract

The MAGhaler (Mundipharma GmbH) is a multidose dry powder inhaler (DPI) containing a novel formulation of drug and lactose compacted by an isostatic pressing technique (GGU GmbH). On actuation, a precise dose is metered from a compacted ring-shaped drug tablet. In this study, the lung deposition of salbutamol from this device has been assessed. Ten healthy non-smoking subjects completed a two-way cross-over study assessing the pulmonary deposition of salbutamol (200 microg) from the MAGhaler at high (60 l/min) and low (30 l/min) peak inhaled flow rates (PIFRs), representing maximal and sub-maximal inspiratory efforts. The formulation was radiolabelled with 99mTc, and lung and oropharyngeal depositions were quantified by gamma scintigraphyThe mean (SD)% ofthe delivered dose deposited in the lungs was 26.4 (4.3)% at 60 l/min and 21.1 (5.1)% at 30 l/min (P < 0.05), corresponding to mean lung depositions of 52.8 and 42.2 microg salbutamol, respectively. The distribution of drug within different lung regions did not vary significantly with inhaled flow rate. The data provided proof of concept for the novel inhaler device and the innovative drug formulation. In comparison with previous deposition data obtained with other DPIs, the lung deposition was relatively high, relatively reproducible (coefficient of variation 16% at 60 l/min) and relatively insensitive to the change in peak inhaled flow rate.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12477219     DOI: 10.1053/rmed.2002.1387

Source DB:  PubMed          Journal:  Respir Med        ISSN: 0954-6111            Impact factor:   3.415


  3 in total

Review 1.  The Impact of Inspiratory Flow Rate on Drug Delivery to the Lungs with Dry Powder Inhalers.

Authors:  Jeffry Weers; Andy Clark
Journal:  Pharm Res       Date:  2016-10-13       Impact factor: 4.200

Review 2.  The Confusing World of Dry Powder Inhalers: It Is All About Inspiratory Pressures, Not Inspiratory Flow Rates.

Authors:  Andrew R Clark; Jeffry G Weers; Rajiv Dhand
Journal:  J Aerosol Med Pulm Drug Deliv       Date:  2019-10-31       Impact factor: 2.849

3.  Experimental Evaluation of Dry Powder Inhalers during Inhalation and Exhalation Using a Model of the Human Respiratory System (xPULM™).

Authors:  Richard Pasteka; Lara Alina Schöllbauer; Joao Pedro Santos da Costa; Radim Kolar; Mathias Forjan
Journal:  Pharmaceutics       Date:  2022-02-24       Impact factor: 6.321