Literature DB >> 12477217

Reduction of variability of exhaled nitric oxide in healthy volunteers.

I van der Lee1, J M M van den Bosch, P Zanen.   

Abstract

Exhaled nitric oxide (eNO) is elevated in patients with asthma in contrast to healthy subjects, although the variability is high. In this study, we tried to reduce the variability of eNO in healthy subjects. We measured eNO using ERS guidelines with a fixed exhalation flow of 250 ml/s in 117 (72 women, 45 men) non-smoking healthy subjects and correlated this to antropometric data and standard lung function measurements. Using a model previously defined by Hyde et al., we selected parameters that were likely to have a high correlation with eNO. ENO was log-normally distributed. The normal values for eNO are significantly (P < 0.001) different for men and women: in women mean ln eNO levels (SD) were 1.49 (0.34), in men 1.74 (0.41) (back-transformed value 4.43 resp. 5.73 ppb). Using multiple regression analysis, only In D(m,CO), InTLC and In sG(aw) showed a significant positive correlation with In eNO in men, although only 20% of the variability of eNO could be explained. In women no correlation was observed and only 5% ofthe variability was explained. The high variability of eNO could only partly be explained in men, which makes the use of reference equations not very helpful.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12477217     DOI: 10.1053/rmed.2002.1390

Source DB:  PubMed          Journal:  Respir Med        ISSN: 0954-6111            Impact factor:   3.415


  4 in total

Review 1.  Exhaled nitric oxide measurements: clinical application and interpretation.

Authors:  D R Taylor; M W Pijnenburg; A D Smith; J C De Jongste
Journal:  Thorax       Date:  2006-09       Impact factor: 9.139

2.  Exhaled nitric oxide in asthma: progress since the introduction of standardized methodology.

Authors:  Natalia M Grob; Raed A Dweik
Journal:  J Breath Res       Date:  2008-09       Impact factor: 3.262

3.  Reference values for exhaled nitric oxide (reveno) study.

Authors:  Mario Olivieri; Giorgio Talamini; Massimo Corradi; Luigi Perbellini; Antonio Mutti; Claudio Tantucci; Mario Malerba
Journal:  Respir Res       Date:  2006-06-30

4.  Correlation between fractional exhaled nitric oxide and Asthma Control Test score and spirometry parameters in on-treatment-asthmatics in Ho Chi Minh City.

Authors:  Vinh Nhu Nguyen; Niels H Chavannes
Journal:  J Thorac Dis       Date:  2020-05       Impact factor: 2.895

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.