Literature DB >> 12473999

Maximum clenching force of patients with moderate loss of posterior tooth support: a pilot study.

Charles H Gibbs1, Kenneth J Anusavice, Henry M Young, Jack S Jones, Josephine F Esquivel-Upshaw.   

Abstract

STATEMENT OF PROBLEM: Patients who have lost moderate posterior tooth support may also lose clenching force as a result of sensitivity to increased loading to the remaining teeth and possibly a loss of muscle strength, because clenching forces are limited to avoid stress to the remaining teeth. Few studies have correlated moderate posterior tooth loss with maximum clenching force.
PURPOSE: The purpose of this pilot study was to test the hypothesis that moderate loss of posterior tooth support will have a significant effect on maximum clenching force.
MATERIAL AND METHODS: The maximum clenching force of 44 adults, ages 28 to 76 (mean 46), with posterior tooth loss was compared with the maximum clenching force of a control group of 20 healthy full dentition adults, ages 18 to 55 (mean 30), by use of a bilateral strain-gauged transducer. The transducer consisted of 2 stainless steel plates separated by a steel sphere that balanced occlusal forces between right and left sides. Acrylic resin pads were fabricated for each patient to protect the cusps of the teeth. The overall accuracy was found to be within 2.3% of full scale over a range of 0 to 4000 N (0 to 900 lbs). The calibration reliability of the system was checked frequently by use of a dead weight of 222 N (50 lbs). Clenching forces were supported by first and second molars and second premolars when possible. The instrumentation, methods, and operator were the same for both groups. A 2-tailed Student t test (alpha=0.01) and a pooled estimate of the mean were used to determine possible statistical significance. To test for possible correlations between clenching force and lost tooth support and between clenching force and age, a linear regression correlation coefficient R was calculated.
RESULTS: For the 44 subjects with posterior tooth loss, the mean clenching force was 462 N (104 lbs), with a range of 98 to 1031 N (22 to 232 lbs). This compares with a mean of 720 N (162 lbs) with a range of 244 to 1243 N (55 to 280 lbs) for the full-dentition subjects. A 2-tailed t test showed that the average difference of 258 N (58 lbs) between the 2 groups was significant (P< or =.01). There was only a moderate negative association between clenching strength and loss of mandibular tooth support (R = -0.35). Clenching force was not well correlated with age as indicated by low R values (R = 0.21, missing tooth group and R = -0.03, full dentition group).
CONCLUSION: Within the limitations of this study the maximum clenching force was less (P< or =.01), by 258 N (58 lbs) on average, in subjects with moderate loss of posterior tooth support. Loss of maximum clenching force was associated with a modest negative correlation to the number of missing teeth in the mandibular arch (R = -0.35). The range of clenching force was surprisingly large for both the missing tooth (98 to 1031 N) and full dentition (244 to 1243 N) groups.

Entities:  

Mesh:

Year:  2002        PMID: 12473999     DOI: 10.1067/mpr.2002.129062

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  14 in total

1.  Engineering long term clinical success of advanced ceramic prostheses.

Authors:  Dianne Rekow; Van P Thompson
Journal:  J Mater Sci Mater Med       Date:  2007-01       Impact factor: 3.896

2.  Clinical Condition of the Oral Cavity in the Adult Polish Population below 70 Years of Age after Myocardial Infarction-A Case-Control Study.

Authors:  Marcin Szerszeń; Bartłomiej Górski; Jan Kowalski
Journal:  Int J Environ Res Public Health       Date:  2022-06-14       Impact factor: 4.614

3.  Comparison of chamfer and deep chamfer preparation designs on the fracture resistance of zirconia core restorations.

Authors:  Ezatollah Jalalian; Roghayeh Rostami; Berivan Atashkar
Journal:  J Dent Res Dent Clin Dent Prospects       Date:  2011-06-14

4.  Occlusion and Temporomandibular Function among Subjects with Mandibular Distal Extension Removable Partial Dentures.

Authors:  N H J Creugers; D J Witter; A Van 't Spijker; A E Gerritsen; C M Kreulen
Journal:  Int J Dent       Date:  2010-07-05

5.  The effect of preparation design on the fracture resistance of zirconia crown copings (computer associated design/computer associated machine, CAD/CAM system).

Authors:  E Jalalian; B Atashkar; R Rostami
Journal:  J Dent (Tehran)       Date:  2011-09-30

6.  Awareness of Clenching and Underweight are Risk Factors for Onset of Crowding in Young Adults: A Prospective 3-Year Cohort Study.

Authors:  Naoki Toyama; Daisuke Ekuni; Ayano Taniguchi-Tabata; Kota Kataoka; Mayu Yamane-Takeuchi; Kohei Fujimori; Terumasa Kobayashi; Daiki Fukuhara; Koichiro Irie; Tetsuji Azuma; Yoshiaki Iwasaki; Manabu Morita
Journal:  Int J Environ Res Public Health       Date:  2019-02-26       Impact factor: 3.390

7.  Long-Term Fatigue and Its Probability of Failure Applied to Dental Implants.

Authors:  María Prados-Privado; Juan Carlos Prados-Frutos; Sérgio Alexandre Gehrke; Mariano Sánchez Siles; José Luis Calvo Guirado; José Antonio Bea
Journal:  Biomed Res Int       Date:  2016-07-19       Impact factor: 3.411

8.  Fracture Strength of Aged Monolithic and Bilayer Zirconia-Based Crowns.

Authors:  Deborah Pacheco Lameira; Wilkens Aurélio Buarque e Silva; Frederico Andrade e Silva; Grace M De Souza
Journal:  Biomed Res Int       Date:  2015-10-21       Impact factor: 3.411

9.  Maximum occlusal bite force in pre-school children with different occlusal patterns.

Authors:  Elham Abu-Alhaija; Arwa I Owais; Hiba Obaid
Journal:  J Clin Exp Dent       Date:  2018-11-01

10.  Effect of crown to implant ratio and implantoplasty on the fracture resistance of narrow dental implants with marginal bone loss: an in vitro study.

Authors:  Bruno Leitão-Almeida; Octavi Camps-Font; André Correia; Javier Mir-Mari; Rui Figueiredo; Eduard Valmaseda-Castellón
Journal:  BMC Oral Health       Date:  2020-11-19       Impact factor: 2.757

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.