Ultrasound properties of human prostate tissue during heating.

A E Worthington1, J Trachtenberg, M D Sherar.   

Abstract

Changes in the ultrasound (US) properties of tissue during heating affect the delivery of US thermal therapy and may provide a basis for US image monitoring of thermal therapy. The US attenuation coefficient and backscatter power of fresh human prostate tissue were measured as the tissue was heated. Samples of human prostate were obtained directly from autopsies and heated rapidly to final temperatures of 45 degrees C, 50 degrees C, 55 degrees C, 60 degrees C and 65 degrees C. A 5.0-MHz transducer was scanned in a raster pattern over the tissue and radiofrequency (RF) data were collected at 36 uncorrelated positions. Both attenuation and backscatter were measured over the frequency range 3.5 to 7.0 MHz at each min of a 30-min heating. Little change was observed in attenuation or backscatter at 55 degrees C or less. The attenuation coefficient and backscatter power increased by factors of 1.25 and 5, respectively, during the 60 degrees C heating. During the 65 degrees C heating, the same properties showed increases by factors of 2.7 and 9.

Entities:  

Mesh:

Year:  2002        PMID: 12467858     DOI: 10.1016/s0301-5629(02)00577-x

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  8 in total

1.  Direct thermal dose control of constrained focused ultrasound treatments: phantom and in vivo evaluation.

Authors:  Dhiraj Arora; Daniel Cooley; Trent Perry; Mikhail Skliar; Robert B Roemer
Journal:  Phys Med Biol       Date:  2005-04-06       Impact factor: 3.609

2.  Cylindrical illumination with angular coupling for whole-prostate photoacoustic tomography.

Authors:  Brittani Bungart; Yingchun Cao; Tiffany Yang-Tran; Sean Gorsky; Lu Lan; Darren Roblyer; Michael O Koch; Liang Cheng; Timothy Masterson; Ji-Xin Cheng
Journal:  Biomed Opt Express       Date:  2019-02-22       Impact factor: 3.732

3.  Considerations for theoretical modelling of thermal ablation with catheter-based ultrasonic sources: implications for treatment planning, monitoring and control.

Authors:  Punit Prakash; Chris J Diederich
Journal:  Int J Hyperthermia       Date:  2012       Impact factor: 3.914

4.  Development of Tough Hydrogel Phantoms to Mimic Fibrous Tissue for Focused Ultrasound Therapies.

Authors:  Yashwanth Nanda Kumar; Zorawar Singh; Yak-Nam Wang; George R Schade; Wayne Kreider; Matthew Bruce; Eli Vlaisavljevich; Tatiana D Khokhlova; Adam D Maxwell
Journal:  Ultrasound Med Biol       Date:  2022-06-10       Impact factor: 3.694

5.  Feasibility of A-mode ultrasound attenuation as a monitoring method of local hyperthermia treatment.

Authors:  Noraida Abd Manaf; Maizatul Nadwa Che Aziz; Dzulfadhli Saffuan Ridzuan; Maheza Irna Mohamad Salim; Asnida Abd Wahab; Khin Wee Lai; Yan Chai Hum
Journal:  Med Biol Eng Comput       Date:  2016-04-02       Impact factor: 2.602

Review 6.  Modelling of endoluminal and interstitial ultrasound hyperthermia and thermal ablation: applications for device design, feedback control and treatment planning.

Authors:  Punit Prakash; Vasant A Salgaonkar; Chris J Diederich
Journal:  Int J Hyperthermia       Date:  2013-06       Impact factor: 3.914

7.  Clinical validation of real-time tissue change monitoring during prostate tissue ablation with high intensity focused ultrasound.

Authors:  Narendra T Sanghvi; Wo-Hsing Chen; Roy Carlson; Clint Weis; Ralf Seip; Toyoaki Uchida; Michael Marberger
Journal:  J Ther Ultrasound       Date:  2017-09-13

8.  Experimental study of beam distortion due to fiducial markers during salvage HIFU in the prostate.

Authors:  Marina Bakaric; Eleanor Martin; Panayiotis S Georgiou; Benjamin T Cox; Heather Payne; Bradley E Treeby
Journal:  J Ther Ultrasound       Date:  2018-03-22
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.