Literature DB >> 12467784

Evaluation of the Cobas AmpliPrep/Cobas Amplicor HIV-1 Monitor Ultrasensitive Test: comparison with the Cobas Amplicor HIV-1 Monitor test (manual specimen preparation).

Annemarie Berger1, Lina Scherzed, Martin Stürmer, Wolfgang Preiser, Hans W Doerr, Holger F Rabenau.   

Abstract

In this preliminary study, we evaluated the performance of the Cobas AmpliPrep/Cobas Amplicor HIV-1 Monitor Ultrasensitive Test (CAP; Roche Molecular Systems, Branchburg, NJ) for automated specimen preparation and quantitative detection of human immunodeficiency virus type 1 (HIV-1) RNA and compared it to the Cobas Amplicor HIV-1 Monitor Ultrasensitive Test (MCA; Roche), which includes a manual sample preparation protocol. A dilution panel of a patient sample was prepared. Additionally, 584 EDTA plasma samples were collected from HIV-1 infected patients. Reproducibility was estimated with six assay runs using the dilution panel. The inter-assay coefficient of variation ranged from 39.4 to 48.4% (CAP assay) and from 34.3 to 45.6% (MCA assay), whereas the intra-assay coefficient of variation ranged from 6.2 to 58.0% (CAP assay) and from 4.4 to 57.3% (MCA assay). Comparison of CAP assay results with the HIV-1 copy number of the dilution panel determined by the MCA assay resulted in a good agreement, although the CAP results were found to be slightly lower. A significant correlation between both test systems was found when clinical samples were analyzed. The mean viral load of 152 samples, which were within the linear range of both tests, was 3.70 log(10) HIV-1 copies/ml by the CAP assay compared to 3.73 by the MCA assay. In conclusion, we could demonstrate that the new Cobas AmpliPrep/Cobas Amplicor HIV Monitor Ultrasensitive Test is reproducible and sensitive. In comparison to the assay with manual extraction, no significant difference in HIV-1 RNA copy numbers was observed.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12467784     DOI: 10.1016/s1386-6532(02)00185-3

Source DB:  PubMed          Journal:  J Clin Virol        ISSN: 1386-6532            Impact factor:   3.168


  9 in total

1.  Impact of the COBAS AmpliPrep/COBAS AMPLICOR HIV-1 MONITOR Test, Version 1.5, on clinical laboratory operations.

Authors:  Jeffrey J Germer; Jordan L Bendel; Craig A Dolenc; Sarah R Nelson; Amanda L Masters; Tara M Gerads; Jayawant N Mandrekar; P Shawn Mitchell; Joseph D C Yao
Journal:  J Clin Microbiol       Date:  2007-07-18       Impact factor: 5.948

2.  Performance of the new Roche Cobas AmpliPrep-Cobas TaqMan version 2.0 human immunodeficiency virus type 1 assay.

Authors:  Lesley Scott; Sergio Carmona; Wendy Stevens
Journal:  J Clin Microbiol       Date:  2009-08-05       Impact factor: 5.948

3.  Evaluation of an upgraded version of the Roche Cobas AmpliPrep/Cobas TaqMan HIV-1 test for HIV-1 load quantification.

Authors:  F Damond; V Avettand-Fenoel; G Collin; B Roquebert; J C Plantier; A Ganon; D Sizmann; R Babiel; J Glaubitz; M L Chaix; F Brun-Vezinet; D Descamps; C Rouzioux
Journal:  J Clin Microbiol       Date:  2010-02-03       Impact factor: 5.948

4.  Comparison of the LCx human immunodeficiency virus (HIV) RNA quantitative, RealTime HIV, and COBAS AmpliPrep-COBAS TaqMan assays for quantitation of HIV type 1 RNA in plasma.

Authors:  Vincent Foulongne; Brigitte Montes; Marie-Noelle Didelot-Rousseau; Michel Segondy
Journal:  J Clin Microbiol       Date:  2006-08       Impact factor: 5.948

5.  Evaluation of the COBAS AmpliPrep-total nucleic acid isolation-COBAS TaqMan hepatitis B virus (HBV) quantitative test and comparison to the VERSANT HBV DNA 3.0 assay.

Authors:  Christophe Ronsin; Anne Pillet; Corinne Bali; Gérard-Antoine Denoyel
Journal:  J Clin Microbiol       Date:  2006-04       Impact factor: 5.948

6.  Cross-platform analysis of HIV-1 RNA data generated by a multicenter assay validation study with wide geographic representation.

Authors:  Cheryl Jennings; Brian Harty; Suzanne Granger; Carrie Wager; John A Crump; Susan A Fiscus; James W Bremer
Journal:  J Clin Microbiol       Date:  2012-06-12       Impact factor: 5.948

7.  Human immunodeficiency virus type 1 (HIV-1) plasma load discrepancies between the Roche COBAS AMPLICOR HIV-1 MONITOR Version 1.5 and the Roche COBAS AmpliPrep/COBAS TaqMan HIV-1 assays.

Authors:  F Damond; B Roquebert; A Bénard; G Collin; M Miceli; P Yéni; F Brun-Vezinet; D Descamps
Journal:  J Clin Microbiol       Date:  2007-08-22       Impact factor: 5.948

8.  Performance of three commercial viral load assays, Versant human immunodeficiency virus type 1 (HIV-1) RNA bDNA v3.0, Cobas AmpliPrep/Cobas TaqMan HIV-1, and NucliSens HIV-1 EasyQ v1.2, testing HIV-1 non-B subtypes and recombinant variants.

Authors:  Africa Holguín; Marisa López; Mar Molinero; Vincent Soriano
Journal:  J Clin Microbiol       Date:  2008-07-02       Impact factor: 5.948

9.  Evaluation of the Upgraded Version 2.0 of the Roche COBAS® AmpliPrep/COBAS® TaqMan HIV-1 Qualitative Assay in Central African Children.

Authors:  C D Mossoro-Kpinde; M A Jenabian; J C Gody; L Robin; P Talla; Jdd Longo; G Grésenguet; L Belec
Journal:  Open AIDS J       Date:  2016-08-05
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.