Literature DB >> 12464445

Reproducibility and treatment planning advantages of a carbon fiber relocatable head fixation system.

Arthur J Olch1, Robert S Lavey.   

Abstract

INTRODUCTION: An all carbon fiber head fixation system, VBH HeadFix Arc ('HeadFix') modified to optimize conformal radiation therapy, is described and its treatment planning and delivery advantages, positional accuracy and X-ray attenuation are presented.
MATERIAL AND METHODS: Serial radiation field isocenter measurements were made from weekly anterior-posterior (AP) and lateral port films taken of 13 children undergoing fractionated external beam radiation therapy for primary brain tumors. Measurements were also made of radiation transmission through the components of the HeadFix system. RESULTS AND
CONCLUSION: The mean deviation between simulation and port films in each of the orthogonal directions was 0.8-1.2 mm and the mean 3 dimensional deviation was 1.8+/-0.6 mm. The modified HeadFix system components attenuate between 2 and 4% of the incident beam, allowing a wider range of beam directions for conformal therapy than the previously reported system.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12464445     DOI: 10.1016/s0167-8140(02)00282-7

Source DB:  PubMed          Journal:  Radiother Oncol        ISSN: 0167-8140            Impact factor:   6.280


  4 in total

1.  Semi-robotic 6 degree of freedom positioning for intracranial high precision radiotherapy; first phantom and clinical results.

Authors:  Jürgen Wilbert; Matthias Guckenberger; Bülent Polat; Otto Sauer; Michael Vogele; Michael Flentje; Reinhart A Sweeney
Journal:  Radiat Oncol       Date:  2010-05-26       Impact factor: 3.481

2.  Dosimetric Effects of Head and Neck Immobilization Devices on Multi-field Intensity Modulated Radiation Therapy for Nasopharyngeal Carcinoma.

Authors:  Li Chen; Ying-Lin Peng; Shi-Yong Gu; Hui Shen; Dan-Dan Zhang; Wen-Zhao Sun; Jian-Hua Wu; Xiao-Wu Deng
Journal:  J Cancer       Date:  2018-06-14       Impact factor: 4.207

3.  Comparison of stereotactic plans for brain tumors with two different multileaf collimating systems.

Authors:  Livia Marrazzo; Margherita Zani; Stefania Pallotta; Daniela Greto; Silvia Scoccianti; Cinzia Talamonti; Giampaolo Biti; Marta Bucciolini
Journal:  J Appl Clin Med Phys       Date:  2014-01-06       Impact factor: 2.102

4.  Evaluation and verification of the QFix EncompassTM couch insert for intracranial stereotactic radiosurgery.

Authors:  Karen Chin Snyder; Ilma Xhaferllari; Yimei Huang; M Salim Siddiqui; Indrin J Chetty; Ning Wen
Journal:  J Appl Clin Med Phys       Date:  2018-06-15       Impact factor: 2.102

  4 in total