Literature DB >> 12462721

Technical note: Sinogram merging to compensate for truncation of projection data in tomotherapy imaging.

H R Hooper1, B G Fallone.   

Abstract

An advantage of helical tomotherapy radiation therapy systems is that on-line megavoltage computed tomography (CT) images can be reconstructed to verify patient positioning. One limitation of such systems is that the field-of-view (FOV) of the photon fan-beam is limited by the aperture size of the binary multileaf collimator (MLC) used to modulate treatment beams. For patients larger than the FOV the acquired sinograms will be truncated causing artifacts in the resultant megavoltage CT images. Computer simulations are used to demonstrate that such artifacts can be eliminated or at least reduced by merging appropriately acquired truncated fan-beam sinograms to form a nontruncated parallel-beam sinogram. The necessary fan-beam sinograms are acquired with the patient translated to different offset locations within the gantry. The parallel-beam sinogram is then used to reconstruct the final CT image. The increase in patient dose due to the acquisition of more than one fan-beam sinogram can be reduced by using properly designed binary MLC fields to block redundant projection rays.

Entities:  

Mesh:

Year:  2002        PMID: 12462721     DOI: 10.1118/1.1514579

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  5 in total

1.  Region of Interest (ROI) Computed Tomography.

Authors:  R Chityala; K R Hoffmann; D R Bednarek; S Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2004

2.  Region of interest (ROI) computed tomography (CT): Comparison with full field of view (FFOV) and truncated CT for a human head phantom.

Authors:  R Chityala; K R Hoffmann; S Rudin; D R Bednarek
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2005

3.  A platform-independent method to reduce CT truncation artifacts using discriminative dictionary representations.

Authors:  Yang Chen; Adam Budde; Ke Li; Yinsheng Li; Jiang Hsieh; Guang-Hong Chen
Journal:  Med Phys       Date:  2017-01       Impact factor: 4.071

4.  Improving image accuracy of region-of-interest in cone-beam CT using prior image.

Authors:  Jiseoc Lee; Jin Sung Kim; Seungryong Cho
Journal:  J Appl Clin Med Phys       Date:  2014-03-06       Impact factor: 2.102

5.  Feasibility study of shutter scan acquisition for region of interest (ROI) digital tomosynthesis.

Authors:  Dohyeon Kim; Byungdu Jo; Donghoon Lee; Haenghwa Lee; Sunghoon Choi; Hyemi Kim; Zhen Chao; Seungyeon Choi; Hee-Joung Kim
Journal:  J Appl Clin Med Phys       Date:  2018-03-01       Impact factor: 2.102

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.