An evaluation of gating window size, delivery method, and composite field dosimetry of respiratory-gated IMRT.

Geoffrey D Hugo1, Nzhde Agazaryan, Timothy D Solberg.   

Abstract

A respiratory gating system has been developed based on a commercial patient positioning system. The purpose of this study is to investigate the ability of the gating system to reproduce normal, nongated IMRT operation and to quantify the errors produced by delivering a nongated IMRT treatment onto a moving target. A moving phantom capable of simultaneous two-dimensional motion was built, and an analytical liver motion function was used to drive the phantom. Studies were performed to assess the effect of gating window size and choice of delivery method (segmented and dynamic multileaf collimation). Additionally, two multiple field IMRT cases were delivered to quantify the error in gated and nongated IMRT with motion. Dosimetric error between nonmoving and moving deliveries is related to gating window size. By reducing the window size, the error can be reduced. Delivery error can be reduced for both dynamic and segmented delivery with gating. For the implementation of dynamic IMRT delivery in this study, dynamic delivery was found to generate larger delivery errors than segmented delivery in most cases studied. For multiple field IMRT delivery, the largest errors were generated in regions where high field modulation was present parallel to the axis of motion. Gating was found to reduce these large errors to clinically acceptable levels.

Entities:  

Mesh:

Year:  2002        PMID: 12462716     DOI: 10.1118/1.1514578

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  7 in total

1.  Feasibility study on inverse four-dimensional dose reconstruction using the continuous dose-image of EPID.

Authors:  Inhwan Jason Yeo; Jae Won Jung; Byong Yong Yi; Jong Oh Kim
Journal:  Med Phys       Date:  2013-05       Impact factor: 4.071

2.  Dosimetric evaluation of radiation dose rate effect in respiratory gated intensity modulated radiation therapy.

Authors:  C Khamfongkhruea; C Tannanonta; S Thongsawad
Journal:  Biomed Imaging Interv J       Date:  2012-01-01

3.  Evaluation of integrated respiratory gating systems on a Novalis Tx system.

Authors:  Zheng Chang; Tonghai Liu; Jing Cai; Qing Chen; Zhiheng Wang; Fang-Fang Yin
Journal:  J Appl Clin Med Phys       Date:  2011-04-04       Impact factor: 2.102

4.  A study of quantitative indicators for slice sorting in cine-mode 4DCT.

Authors:  Changhwan Kim; Hojae Kim; Sung-Woo Kim; Youngmoon Goh; Min-Jae Park; Hojin Kim; Chiyoung Jeong; Byungchul Cho; Eun Kyung Choi; Sang-Wook Lee; Sang Min Yoon; Su Ssan Kim; Jin-Hong Park; Jinhong Jung; Si Yeol Song; Jungwon Kwak
Journal:  PLoS One       Date:  2022-08-26       Impact factor: 3.752

5.  Magnitude of shift of tumor position as a function of moderated deep inspiration breath-hold: An analysis of pooled data of lung patients with active breath control in image-guided radiotherapy.

Authors:  K R Muralidhar; P Narayana Murthy; D Shankar Mahadev; K Subramanyam; G Sudarshan; A Krishnam Raju
Journal:  J Med Phys       Date:  2008-10

6.  Phase versus amplitude sorting of 4D-CT data.

Authors:  Nicole Wink; Christoph Panknin; Timothy D Solberg
Journal:  J Appl Clin Med Phys       Date:  2006-02-15       Impact factor: 2.102

7.  Dosimetric characteristics of a new linear accelerator under gated operation.

Authors:  Sergey Kriminski; Alex N Li; Timothy D Solberg
Journal:  J Appl Clin Med Phys       Date:  2006-02-15       Impact factor: 2.102

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.