Literature DB >> 12462629

Analysis of polar pesticides in water and wine samples by automated in-tube solid-phase microextraction coupled with high-performance liquid chromatography-mass spectrometry.

Jingcun Wu1, Charalambos Tragas, Heather Lord, Janusz Pawliszyn.   

Abstract

A simple and sensitive method for the determination of polar pesticides in water and wine samples was developed by coupling automated in-tube solid-phase microextraction (SPME) to high-performance liquid chromatography-electrospray ionization mass spectrometry (HPLC-ESI-MS). To achieve optimum performance, the conditions for both the in-tube SPME and the ESI-MS detection were investigated. In-tube SPME conditions were optimized by selecting the appropriate extraction parameters, especially the stationary phases used for SPME. For the compounds studied, a custom-made polypyrrole (PPY)-coated capillary showed superior extraction efficiency as compared to several commercial capillaries tested, and therefore, it was selected for in-tube SPME. The influence of the ethanol content on the performance of in-tube SPME was also investigated. It was found that the amount of pesticides extracted decreased with the increase of ethanol content in the solutions. The ESI-MS detection conditions were optimized as follows: nebulizer gas, N2 (30 p.s.i.; 1 p.s.i.=6894.76 Pa); drying gas, N2 (10 l/min, 350 degrees C); capillary voltage, 4500 V; ionization mode, positive; mass scan range, 50-350 amu; fragmentor voltage, variable depending on the ions selected. Due to the high extraction efficiency of the PPY coating and the high sensitive mass detection, the detection limits (S/N = 3) of this method for the compounds studied are in the range of 0.01 to 1.2 ng/ml, which are more than one order of magnitude lower than those of the previous in-tube SPME-HPLC-UV method. A linear relationship was obtained for each analyte in the concentration range of 0.5 to 200 ng/ml with MS detection. This method was applied to the analysis of phenylurea and carbamate pesticides in spiked water and wine samples.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12462629     DOI: 10.1016/s0021-9673(02)01072-5

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  3 in total

1.  Photo-induced fluorescence of fluometuron in a continuous-flow multicommutation assembly.

Authors:  I Cydzik; J R Albert-García; J Martínez Calatayud
Journal:  J Fluoresc       Date:  2006-12-13       Impact factor: 2.217

2.  A nanocomposite prepared from a polypyrrole deep eutectic solvent and coated onto the inner surface of a steel capillary for electrochemically controlled microextraction of acidic drugs such as losartan.

Authors:  Hamid Asiabi; Yadollah Yamini; Maryam Shamsayei; Jamshid Azarnia Mehraban
Journal:  Mikrochim Acta       Date:  2018-02-12       Impact factor: 5.833

3.  Atrazine adsorption removal with nylon6/polypyrrole core-shell nanofibers mat: possible mechanism and characteristics.

Authors:  Bi-Yi Yang; Yang Cao; Fei-Fei Qi; Xiao-Qing Li; Qian Xu
Journal:  Nanoscale Res Lett       Date:  2015-05-06       Impact factor: 4.703

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.